Z Series RO System by GE Osmonics
2.1
Installation Considerations
1. RO
Unit:
a. Location: The Z Series RO unit is free standing and should be situated
with 2 feet of clearance on all sides. Locate away from any obstructions
to provide room for access to the power cord and the water connections.
b. Dimensions: Height – 74”; Width – 30”; Depth – 32.5”
c. Weight: Between 390 and 630 pounds depending on the RO unit model.
2.
Product Divert Controller:
a. Location: Mount the Product Divert Controller on a highly visible section
of the wall near an 115VAC electrical outlet and within 5 feet of the RO
unit control box.
b. Dimensions: Height – 11.5”; Width – 9.5”; Depth – 6”
3.
Product Divert Valve Assembly:
a. Location: Mount the Product Divert Valve Assembly on the wall between
the RO unit and the storage tank or the next purification device in the
treatment stream. The valve assembly should be within 5 feet of the
Product Divert Controller. See the Product Divert Valve installation
drawing in Chapter Six for specific details.
4.
Temperature Alarm Monitor:
a. Location: Mount the Temperature Alarm Monitor on an accessible and a
highly visible section of the wall within 5 feet of the temperature probe.
b. Dimensions: Height – 4.5”; Width – 7.5”; Depth – 6”.
5. Temperature
Probe:
a. Location: The temperature probe is installed in the direct flow of feed
water in the run of a 1” or larger piping tee after the first piece of pre-
treatment equipment before the RO unit. See the temperature probe
installation drawing in Chapter Six for specific details.
1238339b – 16Oct03
2 - 3
Installation Guidelines and Instructions
Summary of Contents for Osmonics Z-10000
Page 2: ......
Page 6: ...This page intentionally left blank 1238339b D D 16 Oct 2003 ...
Page 27: ...Z Series RO System by GE Osmonics NOTES 1238339b 16Oct03 1 21 General Information ...
Page 43: ...Z Series RO System by GE Osmonics NOTES 1238339b 16Oct03 3 5 System Operation ...
Page 72: ...Z Series RO System by GE Osmonics NOTES 1238339b 16Oct03 4 28 Routine Maintenance ...
Page 84: ...Z Series RO System by GE Osmonics NOTES 1238339b 16Oct03 5 12 Troubleshooting ...
Page 107: ...Z Series RO System by GE Osmonics 1238339b 16Oct03 6 23 Drawings Z Series RO Fluid Panel ...
Page 119: ...Z Series RO System by GE Osmonics NOTES 1238339b 16Oct03 6 35 Drawings ...
Page 126: ...Z Series RO System by GE Osmonics NOTES 1238339b 16Oct03 7 6 Spare Parts List ...
Page 127: ......