1.11.4 Dimensions & Weights
Dimensions
Height 74
inches
Depth 32.5
inches
Width 29.75
inches
Operating Weight
Indirect Units Lbs. Direct
Units Lbs.
Z-9600 450
Z-6000 390
Z-12000 510
Z-8000 450
Z-14400 630
Z-10000 510
Z-12000
630
1.11.5 Membrane Performance Characteristics
% Salt Rejection
95% Minimum Salt Rejection
Operating Pressure
Direct Feed
225 PSI
±
10 PSI
Indirect Feed
250 PSI
±
10 PSI
1.11.6 Environmental
Requirement
Minimum
Maximum
Ambient Temperature
4°C (39°F)
32°C (90°F)
Storage Temperature
2°C (36°F)
32°C (90°F)
Altitude
N/A
10,000
feet
CAUTION:
This equipment must not be allowed to freeze. Irreparable harm to various components,
including RO membranes may result.
NOTE:
The user/operator should recognize that moisture can be caused by condensation and is
not necessarily an equipment leak. This equipment will function in the presence of
condensation.
1238339b – 16Oct03
1 - 16
General Information
Summary of Contents for Osmonics Z-10000
Page 2: ......
Page 6: ...This page intentionally left blank 1238339b D D 16 Oct 2003 ...
Page 27: ...Z Series RO System by GE Osmonics NOTES 1238339b 16Oct03 1 21 General Information ...
Page 43: ...Z Series RO System by GE Osmonics NOTES 1238339b 16Oct03 3 5 System Operation ...
Page 72: ...Z Series RO System by GE Osmonics NOTES 1238339b 16Oct03 4 28 Routine Maintenance ...
Page 84: ...Z Series RO System by GE Osmonics NOTES 1238339b 16Oct03 5 12 Troubleshooting ...
Page 107: ...Z Series RO System by GE Osmonics 1238339b 16Oct03 6 23 Drawings Z Series RO Fluid Panel ...
Page 119: ...Z Series RO System by GE Osmonics NOTES 1238339b 16Oct03 6 35 Drawings ...
Page 126: ...Z Series RO System by GE Osmonics NOTES 1238339b 16Oct03 7 6 Spare Parts List ...
Page 127: ......