background image

9

Installation Instructions

Electrical Connections 

cont.

4

3-WIRE POWER CORD
INSTALLATION

WARNING: 

The neutral or

ground wire of the power cord must
be connected to the neutral terminal
located in the center of the terminal
block. The power leads must be
connected to the lower left and the
lower right terminals of the terminal
block.

A

Remove the 3 lower terminal screws
from the terminal block. Insert the 3
terminal screws through each power
cord terminal ring and into the lower
terminals of the terminal block. Be
certain that the center wire (white/
neutral) is connected to the center lower
position of the terminal block. Tighten
screws securely into the terminal block.
DO NOT remove the ground strap
connection.

Terminal block
(appearance
may vary)

Ground
plate

Power cord

Ground
strap

Neutral
terminal

B

Skip to Step 8 and proceed with the
installation.

5

4-WIRE POWER CORD
INSTALLATION

WARNING: 

The neutral wire of

the supply circuit must be connected
to the neutral terminal located in the
lower center of the terminal block.
The power leads must be connected
to the lower left and the lower right
terminals of the terminal block. The
4th grounding lead must be connected
to the frame of the range with the
ground plate and the ground screw.

A

Remove the 3 lower terminal screws from
the terminal block. Remove the ground
screw and ground plate and retain them.
Cut and discard the ground strap. DO
NOT DISCARD ANY SCREWS.
Insert the one ground screw into the
power cord ground wire terminal ring,
through the ground plate and into the
frame of the range.
Insert the 3 terminal screws (removed
earlier) through each power cord
terminal ring and into the lower
terminals of the terminal block. Be
certain that the center wire (white/
neutral) is connected to the center lower
position of the terminal block. Tighten
screws securely into the terminal block.

E

Skip to Step 8 and proceed with the
installation.

or

Terminal
block

B

C

D

Ground strap

Ground
strap

Neutral
terminal

Before

After

Terminal
block

Ground
screw

Ground
plate
(grounding
to range)

Summary of Contents for JS905

Page 1: ...IMPORTANT Observe all governing codes and ordinances Note to Installer Be sure to leave these instructions with the consumer Note to Consumer Keep these instructions for future reference Proper insta...

Page 2: ...t 5 beyond the front of the cabinets Cabinets installed above a cooktop must be no deeper than 13 Be sure your appliance is properly installed and grounded by a qualified technician WARNING To reduce...

Page 3: ...ntertop and range cooktop may occur Forcing the cooktop to fit may cause excessive gaps and could break the glass and void the warranty Continued on following page Installation Instructions Pre Instal...

Page 4: ...the door on its handle This could cause dents or scratches Place hands on both sides of the door and close the oven door to the removal position This is half way between the broil stop and fully clos...

Page 5: ...the range see Alternate Construction section AF on page 16 30 ranges conform to U L requirements for 0 spacing from vertical walls below countertops Allow 1 4 minimum clearance at the back wall above...

Page 6: ...and voiding the warranty Center the 30 wide opening over the adjacent cabinets and mark with a straight edge Using a straight edge mark the back line at 23 3 16 from the front edge of the counter Be...

Page 7: ...e leads on the junction block ELECTRICAL REQUIREMENTS CAUTION For personal safety do not use an extension cord with this appliance Remove house fuse or open circuit breaker before beginning installati...

Page 8: ...gh the strain relief and tighten Allow enough slack to easily attach the cord terminals to the terminal block If tabs are present at the end of the winged strain relief they can be removed for better...

Page 9: ...e supply circuit must be connected to the neutral terminal located in the lower center of the terminal block The power leads must be connected to the lower left and the lower right terminals of the te...

Page 10: ...t Conduit B Skip to Step 8 and proceed with the installation 7 4 WIRE CONDUIT INSTALLATION A Loosen the three lower terminal screws from the terminal block Remove the ground screw and ground plate and...

Page 11: ...les in each Install the sleeve anchors into the predrilled concrete holes and install the lag and wall screws through the Anti Tip bracket Make sure the screws are securely tightened To Front Edge of...

Page 12: ...in the front two leveling legs similar to E until the glass overhang touches the countertop Carefully push the range into the opening until the countertop fully engages the control panel The back glas...

Page 13: ...Bottom Edge of Slot Hinge Arm Hinge Notch Notch of Hinge Securely Fitted into Bottom of Hinge Slot Hinge in Locked Position Place the drawer rail on the guides Push the drawer in until it stops Lift t...

Page 14: ...diately Recheck the range wiring connections If change is made to connections retest again If no change is required have building wiring checked for proper connections and voltage It is recommended th...

Page 15: ...rd kit refer to the backguard kit instructions for installation details AA If you use the filler kit place the metal filler piece supplied with the range to the back of the range as shown in the figur...

Page 16: ...from the front of the countertop Be aware that the screws provided are long and may penetrate through the back of the island cabinets In this event use shorter screws not provided or the screws provid...

Page 17: ...17 NOTES...

Page 18: ...18 NOTES...

Page 19: ...19 NOTES...

Page 20: ...20 NOTES...

Reviews: