background image

3

Installation Overview

NOTE:

Be sure to allow a minimum space of 1

1

2

under the filter for removing the sump, to change 
the cartridge.

GXWH04F

GXWH20F

Recommended
shut-off valve

Recommended
shut-off valve

Select Location

Select a location for the filter that is:

protected from freezing.

not exposed to direct sunlight.

It is recommended that a shut-off valve be placed on both sides 
of the filter.

It is recommended that a mounting bracket be used.

Install Fittings and Mounting Bracket

Instructions are for installing fittings supplied with the filter 
(on some models) or the WHKIT onto 3/4

copper plumbing. 

If the unit is to be installed on any other type of tubing (plastic,
PVC, galvanized), different hardware must be purchased. See
instructions with additional hardware purchased, or consult 
a qualified plumber.

Apply about 12

of Teflon tape, in a clockwise

direction, to the pipe threads of each fitting.

DO NOT

use joint compound on any parts.

Use the bracket as a template to find the 
two screw locations. Wood screws are provided. If mounted
onto other surface, use appropriate hardware. 

Drill a 3/16

hole on each marked screw location (optional),

then drive the two wood screws until about 1/4

of thread 

is left. Ensure at least one screw is anchored into wall stud.

Assemble a fitting through the mounting bracket hole to 
the inlet and outlet of the head. Start each fitting by hand 
to make sure they don’t cross thread. Use a 1

1

8

wrench to

tighten fittings firmly. 

DO NOT OVERTIGHTEN.

4

3

2

1

Cut Water Line

WARNING:

A copper or galvanized cold water pipe may be used to ground
electrical outlets in the home. Failure to maintain this ground
path may result in an electric shock hazard. If the cold water pipe
is used to ground electric outlets, please refer to 

Installing the

Ground Wire

section before cutting the pipe.

Turn off the water supply and open a nearby faucet to drain
the water out of the pipes.

Using a tape measure or ruler, measure the distance “D” 
as shown.

NOTE: 

It is recommended that the shut-off valve be placed 

before and after the filter as shown in the 

Installation Overview

illustration.

Select a secure location to install the filter and mounting
bracket. The location should align the filter housing with the
inlet and outlet pipes and should not cause the pipes to bend.
Mark the distance “D” on the pipe. D is about 5

1

4

for

GXWH04F model and 5

3

4

for GXWH20F model.

Using a pipe cutter, cut pipe. Sand (file) the cut ends of the
pipe to assure that they are square and smooth.

NOTE:

Have a bucket and towel available to collect excess water.

3

2

1

Measure to shoulder 

of fittings. Copper
pipe butts against

this shoulder.

D

D

GXWH04F

GXWH20F

Recommended
shut-off valve

Recommended
shut-off valve

GXWH04F

GXWH20F

Teflon tape

STEP-BY-STEP INSTALLATION INSTRUCTIONS

Summary of Contents for GXWH20S

Page 1: ... shut off valve be placed directly upstream of your household filter PROPER INSTALLATION Check with your local public works department for plumbing codes You must follow their guides as you install the Household Water Filtration Housing Use the Household Water Filtration Housing on a potable safe to drink home COLD water supply only The filter cartridge will not purify water or make unsafe water s...

Page 2: ... the canister making sure it is centered and completely seated on the bottom seal Reinstall the filter canister to the unit Tighten filter canister to seal Use canister wrench if necessary Slowly rotate control handle to the FILTER position model GXWH20F or slowly turn on the upstream shut off valve model GXWH04F Press the red pressure release button to remove trapped air Open any downstream fauce...

Page 3: ...gh the mounting bracket hole to the inlet and outlet of the head Start each fitting by hand to make sure they don t cross thread Use a 11 8 wrench to tighten fittings firmly DO NOT OVERTIGHTEN 4 3 2 1 Cut Water Line WARNING A copper or galvanized cold water pipe may be used to ground electrical outlets in the home Failure to maintain this ground path may result in an electric shock hazard If the c...

Page 4: ...oss the filter and tightly clamp using UL approved 1 2 1 bronze grounding clamps at both ends as shown Zinc clamps should not be used on copper plumbing For GXWH04F wire and clamps may be purchased separately from your local hardware store or are available by visiting our Website at ge com or from Parts and Accessories by calling 800 626 2002 U S or 800 663 6060 Canada order part number WHKIT Clea...

Page 5: ...nister which together form a filter pressure vessel Damage to the product caused by accident fire floods or acts of God Incidental or consequential damage caused by possible defects with this appliance its installation or repair For how long after the original purchase One 1 year How do I make a warranty claim Return to the retailer from which it was purchased along with a copy of the Proof of Pur...

Page 6: ...le système de corps On recommande fortement l installation d un robinet d arrêt directement en amont du système de filtration INSTRUCTIONS D INSTALLATION Consulter le service local des travaux publics au sujet des codes de plomberie L installation du corps de filtration d eau doit être conforme aux prescriptions du code de plomberie local Utiliser le corps de filtration d eau uniquement sur une ca...

Page 7: ...placer correctement et bien centrer la cartouche sur le joint du fond Revisser le corps de filtre sur la tête Serrez bien la cartouche à filtre pour le sceller Le cas échéant utilisez une clé à cartouche Rétablir lentement l arrivée d eau au filtre avec la poignée de contrôle modèle GXWH20F ou le robinet d arrêt en amont Appuyer sur le bouton rouge pour permettre l évacuation de l air piégé Ouvrir...

Page 8: ... canalisation d eau froide en cuivre ou en acier galvanisé peut être utilisée pour la mise à la terre des prises d alimentation électrique dans la maison Le défaut de maintenir ce trajet de mise à la terre peut entraîner un risque d électrocution Si la canalisation d eau froide est utilisée pour la mise à la terre des prises d alimentation électrique veuillez consulter la section Installation du f...

Page 9: ...ixé solidement au moyen d attaches en bronze homologuées par UL de dimensions variant entre 1 2 po 1 po à chaque extrémité comme indiqué N utilisez pas d attaches en zinc sur le cuivre Pour le modèle GXWH04F il est possible d acquérir le fil et les attaches séparément chez votre visitant notre site Web à ge com ou en vous adressant à notre service des Pièces et Accessoires au 800 626 2002 aux Etat...

Page 10: ...nt ensemble le récipient de filtre à pression Tout dommage causé au produit par accident incendie inondation ou acte de Dieu Tout dommage fortuit ou indirect causé par des défauts éventuels de cet appareil son installation ou les réparations effectuées Quelle est la durée de la garantie après l achat Un an Comment dois je faire ma réclamation Ramenez le produit au magasin où vous l avez acheté ave...

Page 11: ...11 NOTES NOTAS ...

Page 12: ...comendado que la válvula de cierre sea colocada directamente hacia arriba de su filtro de hogar INSTALACION CORRECTA Consulte con su departamento de obras públicas local para los códigos de plomería Usted debe seguir sus guías a medida que instale el alojamiento de filtración de agua para el hogar Use el alojamiento de filtración de agua para el hogar solamente en un abastecimiento de agua potable...

Page 13: ...culo asegurándose de que esté centrado y completamente asentado sobre el fondo del sello Reinstale el receptáculo del filtro a la unidad Apriete el cartucho del filtro para sellar Use una llave de cartucho si es necesario Lentamente rote la manija de control hasta la posición del FILTRO modelo GXWH20F o gire lentamente la válvula de desconexión de flujo vertical modelo GXWH04F Empuje el botón rojo...

Page 14: ...aje en la entrada y la salida de la cabeza Empiece cada unión con la mano para estar seguro que los hilos no se crucen Use una llave inglesa de 11 8 firmemente NO APRIETE DEMASIADO 4 3 2 1 Corte de la línea de agua ADVERTENCIA Una tubería de cobre o galvanizada de agua fría podría usarse para conectar a tierra los tomacorrientes eléctricos en la casa No mantener esta conexión a tierra podría resul...

Page 15: ... Usted no debe usar abrazaderas de cinc en tubería de cobre Para el modelo GXWH04F el cable y las abrazaderas pueden ser compradas por separado en su ferretería local o están disponibles visitando nuestro Website a ge com o en nuestro Departamento de Partes y Accesorios al 800 626 2002 ordene el número de la parte WHKIT Limpie la tubería de cobre y los extremos del cable con papel de esmeril Se re...

Page 16: ...o del filtro los que juntos forman la vasija de presión del filtro Daños causados al producto debido a accidentes incendio inundaciones o actos de la naturaleza Daños secundarios o por consecuencia causados por posibles defectos en el producto su instalación o reparación Por cuánto tiempo después de la compra Un año Cómo hago la reclamación de la garantía Devuélvala al minorista a quien le compró ...