background image

4

Timer Installation and Application Instructions

Timer cap

Blue reset button

Timer base

Timer seat

Head

2 AAA

batteries

Timer battery installation and change

Insert coin or screwdriver into the slot between
timer cap and base. Gently pry them open and
separate timer base from cap. Install or change 
2 new AAA 1.5 volt batteries. After you have 
the batteries in place, line up the base and cap
and snap them back together.

It is recommended to change the batteries at
least every 2 filter changes, or when the blue
LED light seems dim.

Do not mix old and new batteries. Do not mix
alkaline, standard (carbon-zinc) or rechargeable
(ni-cad, ni-mh, etc.) batteries.

Installation of timer

Hold the timer body in the center and gently
push the timer to its seat at the top of the head
or attach it in a remote location for easy viewing.

Timer reset and application

After new batteries are installed or filter is
changed, push and hold the blue timer reset
button (hold the reset button for approximately
5 seconds). Release the reset button after the
light stops flashing. The timer has been reset.
The light will flash again in 90 days to remind
you that it is time to change the filter.

STEP-BY-STEP INSTALLATION INSTRUCTIONS (cont.)

Installing the Ground Wire

NOTE: 

If your house plumbing is plastic, it would not be used as 

a grounding path, and this step should be skipped.

IMPORTANT:

A copper or galvanized cold water pipe is often used

to ground electrical outlets in the home. 

Grounding protects you

from electrical shock.

The water filter housing may have broken

this ground path. To restore connection, install a 12

″ 

long, 

6-gauge copper wire across the filter, and tightly clamp using 
UL-approved 1/2

–1

bronze grounding clamps at both ends as

shown. Zinc clamps should not be used on copper plumbing. 
For 

GXWH04F

, wire and clamps may be purchased separately

from your local hardware store, or are available by visiting our
Website at ge.com, or from Parts and Accessories by calling
800.626.2002 (U.S.)or 800.663.6060 (Canada)—order part
number WHKIT.

Clean copper pipe and ends of wire with emery paper. Bare
wire is recommended. If insulated wire is used, it should be
stripped 3/4

at each end before cleaning with emery paper.

Attach bronze clamps to copper pipe. Tighten screws.

Attach wire to clamps as shown. Tighten screws.

3

2

1

Clamp

Final Check

Install filter, if not already done. (See Filter Cartridge
Replacement section.)

Slowly turn on water supply.

Check entire system for leaks.

If leaking from fittings, shut off water pressure and tighten or
reseal fittings. If leaking from the canister, tighten the canister
with a wrench.

Open any downstream faucet and allow filter and housing to
flush for 5 minutes.

5

4

3

2

1

Ground wire

Installing the Unit

Align filter assembly with pipe ends, making certain that the

incoming

water supply is going into the filter opening marked

“IN”. It may be necessary to spread the pipe ends apart to
install filter assembly.

Using a 1

1

8

wrench to hold the fitting in place, use a 1

1

4

wrench to tighten the nut. Repeat process for other fittings.

Hang mounting bracket with unit onto previously installed
screws.  Drive two screws to secure unit tightly to the wall if
necessary.

Install a filter into the housing and tighten canister to seal 
(see Filter Cartridge Replacement section). 

4

3

2

1

Attach Fittings to Water Line

Slip a compression nut onto each pipe.

Next, slip the brass ferrule onto each pipe.

2

1

Hex nut

Brass ferrule

Hex nut

Brass ferrule

D

Summary of Contents for GXWH20S

Page 1: ... shut off valve be placed directly upstream of your household filter PROPER INSTALLATION Check with your local public works department for plumbing codes You must follow their guides as you install the Household Water Filtration Housing Use the Household Water Filtration Housing on a potable safe to drink home COLD water supply only The filter cartridge will not purify water or make unsafe water s...

Page 2: ... the canister making sure it is centered and completely seated on the bottom seal Reinstall the filter canister to the unit Tighten filter canister to seal Use canister wrench if necessary Slowly rotate control handle to the FILTER position model GXWH20F or slowly turn on the upstream shut off valve model GXWH04F Press the red pressure release button to remove trapped air Open any downstream fauce...

Page 3: ...gh the mounting bracket hole to the inlet and outlet of the head Start each fitting by hand to make sure they don t cross thread Use a 11 8 wrench to tighten fittings firmly DO NOT OVERTIGHTEN 4 3 2 1 Cut Water Line WARNING A copper or galvanized cold water pipe may be used to ground electrical outlets in the home Failure to maintain this ground path may result in an electric shock hazard If the c...

Page 4: ...oss the filter and tightly clamp using UL approved 1 2 1 bronze grounding clamps at both ends as shown Zinc clamps should not be used on copper plumbing For GXWH04F wire and clamps may be purchased separately from your local hardware store or are available by visiting our Website at ge com or from Parts and Accessories by calling 800 626 2002 U S or 800 663 6060 Canada order part number WHKIT Clea...

Page 5: ...nister which together form a filter pressure vessel Damage to the product caused by accident fire floods or acts of God Incidental or consequential damage caused by possible defects with this appliance its installation or repair For how long after the original purchase One 1 year How do I make a warranty claim Return to the retailer from which it was purchased along with a copy of the Proof of Pur...

Page 6: ...le système de corps On recommande fortement l installation d un robinet d arrêt directement en amont du système de filtration INSTRUCTIONS D INSTALLATION Consulter le service local des travaux publics au sujet des codes de plomberie L installation du corps de filtration d eau doit être conforme aux prescriptions du code de plomberie local Utiliser le corps de filtration d eau uniquement sur une ca...

Page 7: ...placer correctement et bien centrer la cartouche sur le joint du fond Revisser le corps de filtre sur la tête Serrez bien la cartouche à filtre pour le sceller Le cas échéant utilisez une clé à cartouche Rétablir lentement l arrivée d eau au filtre avec la poignée de contrôle modèle GXWH20F ou le robinet d arrêt en amont Appuyer sur le bouton rouge pour permettre l évacuation de l air piégé Ouvrir...

Page 8: ... canalisation d eau froide en cuivre ou en acier galvanisé peut être utilisée pour la mise à la terre des prises d alimentation électrique dans la maison Le défaut de maintenir ce trajet de mise à la terre peut entraîner un risque d électrocution Si la canalisation d eau froide est utilisée pour la mise à la terre des prises d alimentation électrique veuillez consulter la section Installation du f...

Page 9: ...ixé solidement au moyen d attaches en bronze homologuées par UL de dimensions variant entre 1 2 po 1 po à chaque extrémité comme indiqué N utilisez pas d attaches en zinc sur le cuivre Pour le modèle GXWH04F il est possible d acquérir le fil et les attaches séparément chez votre visitant notre site Web à ge com ou en vous adressant à notre service des Pièces et Accessoires au 800 626 2002 aux Etat...

Page 10: ...nt ensemble le récipient de filtre à pression Tout dommage causé au produit par accident incendie inondation ou acte de Dieu Tout dommage fortuit ou indirect causé par des défauts éventuels de cet appareil son installation ou les réparations effectuées Quelle est la durée de la garantie après l achat Un an Comment dois je faire ma réclamation Ramenez le produit au magasin où vous l avez acheté ave...

Page 11: ...11 NOTES NOTAS ...

Page 12: ...comendado que la válvula de cierre sea colocada directamente hacia arriba de su filtro de hogar INSTALACION CORRECTA Consulte con su departamento de obras públicas local para los códigos de plomería Usted debe seguir sus guías a medida que instale el alojamiento de filtración de agua para el hogar Use el alojamiento de filtración de agua para el hogar solamente en un abastecimiento de agua potable...

Page 13: ...culo asegurándose de que esté centrado y completamente asentado sobre el fondo del sello Reinstale el receptáculo del filtro a la unidad Apriete el cartucho del filtro para sellar Use una llave de cartucho si es necesario Lentamente rote la manija de control hasta la posición del FILTRO modelo GXWH20F o gire lentamente la válvula de desconexión de flujo vertical modelo GXWH04F Empuje el botón rojo...

Page 14: ...aje en la entrada y la salida de la cabeza Empiece cada unión con la mano para estar seguro que los hilos no se crucen Use una llave inglesa de 11 8 firmemente NO APRIETE DEMASIADO 4 3 2 1 Corte de la línea de agua ADVERTENCIA Una tubería de cobre o galvanizada de agua fría podría usarse para conectar a tierra los tomacorrientes eléctricos en la casa No mantener esta conexión a tierra podría resul...

Page 15: ... Usted no debe usar abrazaderas de cinc en tubería de cobre Para el modelo GXWH04F el cable y las abrazaderas pueden ser compradas por separado en su ferretería local o están disponibles visitando nuestro Website a ge com o en nuestro Departamento de Partes y Accesorios al 800 626 2002 ordene el número de la parte WHKIT Limpie la tubería de cobre y los extremos del cable con papel de esmeril Se re...

Page 16: ...o del filtro los que juntos forman la vasija de presión del filtro Daños causados al producto debido a accidentes incendio inundaciones o actos de la naturaleza Daños secundarios o por consecuencia causados por posibles defectos en el producto su instalación o reparación Por cuánto tiempo después de la compra Un año Cómo hago la reclamación de la garantía Devuélvala al minorista a quien le compró ...