71
as shown in the table must be entered .
Battery volts
Set units
24 volts
Between 0 and 31
36 volts
Between 32 and 44
48 volts
Between 45 and 69
72 volts
Between 70 and 80
80 volts
Between 81 and 183
36/48 volts
Between 184 and 250
No BDI
Between 251 and 255
The following functions have function numbers larger
than the numbers on the Handset keyboard. To access
these functions, push the CONT key and the number shown
in the following instructions at the same time.
FUNCTION 16 PEDAL POSITION PLUG
( Push CONT and 1 )
This function will allow the adjustment of the pedal position
plug range. Pedal position will reduce the plugging current
to the current value set by this function as the accelerator is
returned to the creep speed position. Maximum plug current
is obtained with the accelerator in the top speed position.
Range
100 to 930 amps (EV100)
150 to 1425 amps (EV200)
Set
0 to 255
Resolution
3.2 amps per set unit (EV100)
5.0 amps per set unit (EV200)
Example
Setting of 20 = 164 amps
To disable the pedal position plug function, adjust the
current value to the same current value as the plug distance
current.
Example: If plug distance current Function 5 is set at 500
amps, then set pedal plug current at 500 amps. With this
setting pedal position will have no effect on plugging
distance.
FUNCTION 17 CARD TYPE SELECTION
( Push CONT and 2 )
This function allows for the selection of the card type used for
your vehicle's application. The table below shows the setting
to select card application type depending on which control
card is used.
EV100
Standard
Speed
Function
with FW
Limit
Regen/FW
STD C/L
0 to 4
20 to 24
40 to 44
High C/L
5 to 9
25 to 29
45 to 49
STD C/L
(Auto plug)
10 to 14
30 to 34
50 to 54
High C/L
(Auto plug)
15 to 19
35 to 39
55 to 59
EV200
Standard
Speed
Function
with FW
Limit
Regen/FW
STD C/L
64 to 68
84 to 88
104 to 108
STD C/L
(Auto plug)
74 to 78
94 to 98
114 to 118
Settings for these function should be made in between the
values shown.
Warning: These settings must be changed by authorized
personnel only, following instructions supplied by the
manufacturer. Card type selection must be made within
the capabilities of the SCR control panel used and the
supporting electro-mechanical devices. Failure to com-
ply with proper application standards could result in
misoperation or damage to the control and/or motors.
FUNCTION 18 STEER PUMP TIME DELAY
( Push CONT and 3 )
This function allows for the selection of steer pump contactor
pick up input, either seat switch or directional switch closing
and adjustment of the time delay for the contactor drop out.
Pick up on seat switch closure and time delay drop out on
seat switch opening.
Range
1.5 to 65 seconds
Setting
Between 0 and 128
Resolution
.5 seconds per set unit
Example:
Setting of 20 = 10.5 seconds
Pick up on directional switch closure and drop out time
delay on directional switch opening.
Range
.5 to 63 seconds
Setting
129 to 255
Resolution
.5 seconds per set unit
Example:
Setting of 149 = 10.5 seconds
Drop out will be 1.5 seconds after the seat switch opens.
Summary of Contents for EV100 LX
Page 3: ...3 EV100LX COMPONENT LOCATIONS ...
Page 4: ...4 EV100LX OUTLINE DRAWING ...
Page 5: ...5 EV100LX WITH SPEED LIMIT AND FW 9 ...
Page 6: ...6 EV100LX WITH REGEN AND FW 9 ...
Page 7: ...7 EV100LX DUAL MOTOR CONTROL 9 ...
Page 8: ...8 EV100LX PUMP CONTROL 9 ...
Page 10: ...10 EV100LX PART NUMBER IDENTIFICATION ...
Page 60: ...6 0 ...
Page 80: ...g GE Industrial Systems EV200LX SUPPLEMENT Page 4 of 5 REV 11 2002 Wiring Diagram ...