5 6
STATUS CODE
-147
D E S C R I P T I O N
No
MEMORY
R E C A L L
C O N T R O L
T Y P E
Pump
Figure 1
SYMPTOM
Pump contactor will open and close, then open and then
can only be closed by opening and closing the key
switch.
POSSIBLE CAUSE
Defective 2 REC circuit.
Check that 2 REC will gate on.
Check for open circuit or loose connection
between 2 REC gate and PZ10. (white/red wire)
Check for open circuit or loose connection 1 REC
and 1C through the 2 REC circuit.
F or R contactor or power tips bouncing open.
Check that power tips on F and R contactor power
tips do not bounce open during operation (ie:
travel over speed bumps or dock plates).
STATUS INDICATION CRITERIA
This status code is displayed when the 2 REC fails to
turn on.
2REC does not turn properly
STATUS CODE
-148
D E S C R I P T I O N
No
MEMORY
R E C A L L
C O N T R O L
T Y P E
Pump
Figure 1
SYMPTOM
Pump contactor will not pick up.
POSSIBLE CAUSE
Defective forward or reverse contactor.
Check for welded forward or reverse contactor
power tips.
Check for sluggish operation of forward or reverse
contactor.
Defective 3 REC circuit.
Check for shorted 3 REC.
Check for shorted 3 REC snubber (23 REC).
Look ahead test for T2 volts. (Less than 12% of battery
volts)
STATUS INDICATION CRITERIA
This status code is displayed when the voltage at T2
is less than 12% of battery volts.
Summary of Contents for EV100 LX
Page 3: ...3 EV100LX COMPONENT LOCATIONS ...
Page 4: ...4 EV100LX OUTLINE DRAWING ...
Page 5: ...5 EV100LX WITH SPEED LIMIT AND FW 9 ...
Page 6: ...6 EV100LX WITH REGEN AND FW 9 ...
Page 7: ...7 EV100LX DUAL MOTOR CONTROL 9 ...
Page 8: ...8 EV100LX PUMP CONTROL 9 ...
Page 10: ...10 EV100LX PART NUMBER IDENTIFICATION ...
Page 60: ...6 0 ...
Page 80: ...g GE Industrial Systems EV200LX SUPPLEMENT Page 4 of 5 REV 11 2002 Wiring Diagram ...