location " Y " on the control card. After installing the handset
tool, plug in the battery and turn on the key switch. The
following is the start-up display sequence that will occur:
START-UP DISPLAY SEQUENCE
Key Switch on
Verify Display Segments for
one second
8888
BDI Display
Diagnostics
or
override
Blank Display
with fault
( No BDI used )
Run Mode
BDI Display
Diagnostics
or
override
Blank Display
with fault
( No BDI used )
Key Switch Off
Display traction
hourmeter for
four seconds
Display pump
hourmeter for
four seconds
or
Blank
( If no Pump SCR used )
NOTE: The vehicle can be operated with the handset
connected,
however, the adjustment knob must be set
fully clockwise to insure the control operates at top
speed.
INSTRUCTIONS
EV100 HANDSET
GENERAL
The Handset is a multi-functional tool to be used with the
EV100/200 LX and LXT SCR controls. The Handset consist
of a Light Emitting Diode (LED) display and a keyboard for
data entry.
PURPOSE:
The purpose of the Handset is to allow
authorized personnel
to perform the following functions:
Monitor existing system fault codes for both traction
and pump SCR systems
Monitor intermittent random status code
Monitor battery state of charge on LXT systems
Monitor hourmeter reading on traction and pump
SCR systems
Monitor or adjust the following control functions:
Creep speed
Controlled Acceleration and 1A time
Current Limit
Steer pump time delay and define signal input
( seat switch or directional switch )
Plugging distance (Current)
Pedal position plug range or disable
1A drop out current or disable
Field Weakening drop out
Field Weakening pick up
Regen braking current limit
Regen braking drop out
Speed limit points ( SL1,SL2, and SL3)
Truck Management fault speed limit
Internal resistance compensation for battery
state of charge indication
Battery voltage ( 36/48 volts is auto ranging )
Selection of card operation type:
Standard traction card selection:
Standard traction with Field Weakening
Standard traction with speed limits
Standard traction with Regen/Field Weaken-
ing
High or low current limit for all of the above.
OPERATION:
Warning : Before connecting or disconnecting the hand-
set tool, jack up the drive wheels of the vehicle, turn off
the key switch, unplug the battery and discharge the
capacitors.
At the SCR control traction card, unplug the " Y plug " if the
dash display is in use and plug in the handset to the plug
GEH-5716
September 1993
GE Electric Vehicle
Systems
Summary of Contents for EV100 LX
Page 3: ...3 EV100LX COMPONENT LOCATIONS ...
Page 4: ...4 EV100LX OUTLINE DRAWING ...
Page 5: ...5 EV100LX WITH SPEED LIMIT AND FW 9 ...
Page 6: ...6 EV100LX WITH REGEN AND FW 9 ...
Page 7: ...7 EV100LX DUAL MOTOR CONTROL 9 ...
Page 8: ...8 EV100LX PUMP CONTROL 9 ...
Page 10: ...10 EV100LX PART NUMBER IDENTIFICATION ...
Page 60: ...6 0 ...
Page 80: ...g GE Industrial Systems EV200LX SUPPLEMENT Page 4 of 5 REV 11 2002 Wiring Diagram ...