4 8
STATUS CODE
-92
D E S C R I P T I O N
No
MEMORY
R E C A L L
C O N T R O L
T Y P E
TMM
STATUS CODE
-91
D E S C R I P T I O N
No
MEMORY
R E C A L L
C O N T R O L
T Y P E
TMM
Figure 1
Figure 1
User defined status code - see OEM instructions manual.
SYMPTOM
Status code flashes on and off.
POSSIBLE CAUSE
User defined status code is displayed by switch closure or
motor brush sensor closure to negative.
See OEM instruction manual for corrective action
required.
Other Causes:
Terminal 3 shorted to negative.
Defective input switch (shorted).
Defective TMM card.
NOTE: When SCR pump control is used with internal
TMM function, input terminal is PA6 on pump logic
card.
STATUS INDICATION CRITERIA
This status code is displayed when the voltage at
terminal 3 of TMM is at zero volts.
STATUS INDICATION CRITERIA
This status code is displayed when the voltage at
terminal 4 of TMM is at zero volts.
User defined status code - see OEM instructions manual.
SYMPTOM
Status code flashes on and off.
POSSIBLE CAUSE
User defined status code is displayed by switch closure or
motor brush sensor closure to negative.
See OEM instruction manual for corrective action
required.
Other Causes:
Terminal 4 shorted to negative.
Defective input switch (shorted).
Defective TMM card.
NOTE: When SCR pump control is used with internal
TMM function, input terminal is PB6 on pump logic
card.
Summary of Contents for EV100 LX
Page 3: ...3 EV100LX COMPONENT LOCATIONS ...
Page 4: ...4 EV100LX OUTLINE DRAWING ...
Page 5: ...5 EV100LX WITH SPEED LIMIT AND FW 9 ...
Page 6: ...6 EV100LX WITH REGEN AND FW 9 ...
Page 7: ...7 EV100LX DUAL MOTOR CONTROL 9 ...
Page 8: ...8 EV100LX PUMP CONTROL 9 ...
Page 10: ...10 EV100LX PART NUMBER IDENTIFICATION ...
Page 60: ...6 0 ...
Page 80: ...g GE Industrial Systems EV200LX SUPPLEMENT Page 4 of 5 REV 11 2002 Wiring Diagram ...