Operation quick reference
© 2015 General Electric Company – All rights reserved.
ADTS 405 Mk2 Instruction Manual-English | 19
3.3 Operation quick reference
The quick reference chart shows normal operation key functions. See
Section 6. ‘Reference and
Specification’
for detailed descriptions of ADTS 405Mk2 functions.
In the key/selection column the following applies:
ALT
-
Key.
[NEXT]
-
Item in menu (soft key).
(SINGLE DOUBLE)
-
Sequence of parameters selected by NEXT key.
(craft1 craft2...)
-
Sequence of names selected by NEXT key.
data entry
-
Enter number from key-pad.
The display shows the main pressure display (Leak Measure or Control mode).
Key/selection
Function and comments
F1-F4
Function keys for menus
ALT Ps
Altitude (Aeronautical units) or Ps (Pressure units)
SPEED Qc
Airspeed (Aeronautical units) or Qc (Pressure units)
MACH Pt
Mach (Aeronautical units) or Pt (Pressure units)
EPR
Engine Pressure Ratio (pressure units only)
ROC Ps RATE
Rate of Climb (Aeronautical units) or Rate of Ps (Pressure units)
RATE TIMER
Start timing rate of change
F1
Wait and time choice 1
F2
Wait and time choice 2
F3
Wait and time choice 3
HOLD
Hold pressure at present value - Press again to release
RATE
Rate of change of Pitot parameter - Press Pitot parameter then RATE
LEAK MEASURE/CONTROL
Switches between measure mode (for leak testing) and control mode
GROUND
Controls Ps to atmospheric pressure and Qc to zero at current rates of change
[GO TO GROUND]
[DISPLAY QFE]
Display local atmospheric (ground) pressure
[DISPLAY QNH]
Display sea level equivalent of local atmospheric pressure
PORT
S
ee Line Switching Unit User Manual
REMOTE
Switches (toggles) between remote and local operation
Prints current parameter values to a stored text file
[ALPHA]
Inserts alphabet character in user text
[BACK]
Deletes last character of user text
data entry
Numeric entry for user text
EXECUTE TEST PROGRAM
Execute down-loaded Test Programs
[NEXT]
Select next listed test program
[PREV]
Select previous listed test program
[RUN]
Execute selected test program
F1
Execute all tests in the test program
F2
Selects and executes a specific test program
HELP
Press HELP then other key for further information
SETUP
Temporary set-up - lost at power down
See QUICK REFERENCE -
SETUP or MINIMUM SETUP
SETUP + F1
Configuration - changes power-up defaults
See QUICK REFERENCE -
CONFIG
Hold F1 while pressing SETUP - then enter PIN
(nudge up)
Increases aim value
(nudge down)
Decreases aim value
0-9
Number entry
-000
Minus sign for first number entry 000 (thousand) if not first number of entry
CLEAR/QUIT
Clear number entry - quit from menu or clear warning message
ENTER
Complete number entry
CLEAR/QUIT + ENTER
ABORT - restart with power-up
Summary of Contents for Druck ADTS 405 R/F Mk2
Page 2: ......
Page 14: ...xii ADTS 405 Mk2 Instruction Manual English 2015 General Electric Company All rights reserved ...
Page 16: ...xiv ADTS 405 Mk2 Instruction Manual English 2015 General Electric Company All rights reserved ...
Page 18: ...xvi ADTS 405 Mk2 Instruction Manual English 2015 General Electric Company All rights reserved ...
Page 121: ......