– 54 –
Diagnostics
Clear Door Diagnostic Tool
The Clear Door (Part #: WX05X20002) provides
technicians with a tool to accurately diagnose
2012 and newer dishwashers. Viewing the wash
zones not only include more accuracy, it will
reduce diagnostic time, reduce repeat calls and will
LQFUHDVHWHFKQLFLDQFRQ¿GHQFH7KHUHPD\DOVREH
situations where the clear door can be used to show
a consumer the dishwasher is operating properly.
3RRUZDVKUHVXOWVFDQEHGXHWRPDQ\GLȺHUHQW
things. The clear door allows operation and
visibility of spray arms including rotation, slow or
non-rotation, leaks between wash components,
restrictions and spray jet pattern.
Proper spray arm speeds have a tolerance of
=/- 5 RPM. The lower spray arm turns clockwise at
approximately 40 RPM. The mid spray arm turns
approximately 30 RPM counter clockwise. The upper
sprayer (some models) cannot be counted but can
be viewed for proper operation.
To Use WX05X20002 Clear Door
1. Place the dishwasher in service mode to
¿OOFLUFXODWHDQGGUDLQ'HWDLOVRQ
Consumer
Error Mode and Service Mode can be found in
dishwasher mini manuals and service guides. All
PRGHOVKDYHWKHVDPHHQWU\GLUHFWLRQV'LȺHUHQW
FRQWUROVKDYHGLȺHUHQWZD\VWRFRPPXQLFDWH
results and progress.
2. Remove the bottom rack for an unobstructed
view of the lower spray arm.
3. Enter Consumer Error Mode.
4. Enter
Service
Mode.
5. Open the dishwasher door all the way to 90
degrees.
6. Place the WX05X20002 Clear Door into the tub
opening starting at the bottom.
WARNING: To prevent any damage, do not close the
dishwasher door when the clear door is in use.
7. The clear door has a latch strike. When pushed
into the latched position, it will activate the door
switch assembly. The dishwasher may not start
if the door is installed to low.
8.
,QLWLDWH)LOOWKHGLVKZDVKHUZLOO¿OOIRUVHFRQGV
9. Initiate the circulate test to view the circulation
system in action.
10. Service mode will initiate a 2 minute circulate
test 30 seconds lower CW, 2 - 3 seconds lower
CCW (will not reach full speed unless dishwasher
is in a main wash cycle) and 30 seconds upper
spray system. This pattern will repeat.
11.
8VHDÀDVKOLJKWIRUEHWWHUYLVLELOLW\/RRNIRU
leaks in all areas including between the wash
components.
12. Determine potential areas for further inspection
and diagnoses.
13.
,QLWLDWHGUDLQWKHGLVKZDVKHUZLOOGUDLQIRU
approximately 70 seconds.
14. Remove the WX05X20002 Clear Door.
15. Proceed with any inspections, diagnoses and
UHSDLUVDVGHWDLOHGLQWKH1R&LUFXODWLRQÀRZ
FKDUW6RPHFRPSRQHQWVPD\FDXVHGLȺHUHQW
symptoms depending on the severity of part
fault.