– 41 –
The sump latches below are shown in the release
position. Each latch has a stop point built in. Turn
the latches to a stop point when unlatching and
latching.
11. Push the sump from the bottom into the tub.
12. Grasp the sump from inside. Use care and DO
NOT USE THE FLOOD FLOAT OR STEP AS A
HANDLE. Tilt and lift to bring the sump into the
WXE%ULQJWKHGUDLQSXPSXSDQGLQ¿UVW7KLV
allows access to disconnect the wiring in the
next step.
NOTE: It is important to route the wire harnesses
in the same locations to prevent future damage
to the harness.
13. Disconnect the circulation pump wiring, drain
SXPSZLULQJDQGÀRRGVZLWFKZLULQJ
14. The sump is now free to remove.
NOTE: Clamp kit (Part #: WD35X10382) can be
used to replace any or all clamps on the sump
assembly. The three hoses located on the sump are
not available as individual parts. The circulation in
ÀRZKRVHLVPROGHGWRWKHFLUFXODWLRQSXPS7KH
hose between the circulation pump and diverter (2)
is molded to the diverter. The hose connecting the
sump to the drain pump (3) has the hose molded to
the drain pump.
Flood Switch
Drain
Pump
Circulation Pump
1
2
3