– 30 –
4. Remove four T-25 Torx screws (two each
side) that secure the inner door to the hinge
assemblies.
5. Slide the inner panel toward the top and the
outer panel to the bottom to disengage the
attachment strips. NOTE: The hinges are
secured to the outer door panel.
6. The attachment strips will disengage from the
outer panel.
7. Support the vent conduit while lifting the inner
door from the outer door panel.
The inner door vent cover must be removed on
model GDF570SxJ to allow the front control console
to be removed from the inner door. Insert two
SRFNHWVW\OHÀDWEODGHVFUHZGULYHUVLQWRWKHYHQW
then turn counter clockwise to remove.
To Separate the Door:
1. Remove the door.
2. Place the door with the outer side on to a
protective surface.
3. Remove two 1/4 in. hex head screws inside the
bottom of the door.
Inner Door Vent Cover