18.6 Full Scale Options
Caution
If you change full scale options,
recalibrate both channels and
replace the meter scale on the
front panel.
CHANNEL A JUMPERS
CHANNEL B JUMPERS
MONITOR
FULL SCALE OPTIONS
INSTALL REMOVE INSTALL REMOVE
0 to 2 g pk
or
0 to 20 m/s
2
pk
W4C
W18D
W4A,B,D
W6C
W2B
W5D
W2A,C,D
W3D
0 to 5 g pk
or
0 to 50 m/s
2
pk
W4A,C
W6C
W4B,D
W18D
W2B,D
W3D
W2A,C
W5D
0 to 10 g pk
or
0 to 100 m/s
2
pk
W4C
W6C
W4A,B,D
W18D
W2B
W3D
W2A,C,D
W5D
0 to 20 g pk
or
0 to 200 m/s
2
pk
W4A
W6C
W4B,C,D
W18D
W2D
W3D
W2A,B,C
W5D
0 to 1 in/s pk
or
0 to 25 mm/s pk
W4A,C
W4B,D
W6C
W18D
W2B,D
W2A,C
W3D
W5D
0 to 2 in/s pk
or
0 to 50 mm/s pk
W4C
W4A,B,D
W6C
W18D
W2B
W2A,C,D
W3D
W5D
0 to 100 mm/s pk
W4A
W4B,C,D
W6C
W18D
W2D
W2A,B,C
W3D
W5D