background image

6

49-7819  

USING THE 

A

IR CONDITIONER

Controls

Cool Mode

Use the COOL mode for cooling. 
To set the COOL mode:
1.   Press the 

MODE 

pad until the 

COOL

 indicator light is 

lit.

2.   Press the 

FAN

 pad to set HIGH, LOW, or SLEEP fan 

speed.

3.   Press

 + or - 

to set the desired temperature between 

61°F and 89°F in 1°F increments.

After settings have been made, the display will change 

back to show the room temperature.
The temperature control is used to maintain the room 

temperature. The compressor will cycle on and off 

to keep the room at the set level of comfort. Set the 

temperature control at a lower number and the indoor 

air will become cooler. Set the temperature control at a 

higher number and the indoor air will become warmer.

NOTE:

 If the air conditioner is off and is then turned on 

while set to COOL, it will take approximately 3 minutes 

for the compressor to start and cooling to begin.

Cooling Descriptions
For Normal Cooling

—Select the COOL mode 

and HIGH or MEDIUM fan speed with a middle set 

temperature.

For Maximum Cooling

—Select the COOL mode  

and HIGH fan speed with a lower set temperature.

For Quieter & Nighttime Cooling

—Select the 

COOL mode and LOW fan speed with a middle set 

temperature.

NOTE: 

If you switch from COOL or DRY mode setting to 

OFF wait 3 minutes before restarting.

DRY Mode—Dehumidification

Use the DRY mode to provide dehumidification only. 

The fan will run at a fixed speed at this setting, so a fan 

speed cannot be set. Keep windows and doors closed 

for the best dehumidifying effects. 

To set the DRY mode:

•Press the 

MODE

 pad until the DRY indicator light is lit.

In the DRY mode, a set temperature will not be 

displayed. After DRY mode has been set, the display will 

change back to show the room temperature.

NOTE: 

If you switch from a DRY setting to OFF or to a 

fan setting, wait at least 3 minutes before switching back 

to a DRY setting.

If using the unit in the DRY mode as a dehumidifier for 

an extended time.
1  . Unplug the power cord.
2.   Connect a drain hose (not included) to the center 

drain port (see page 9, upper drain #8) and lead hose 

to floor drain.

3.   Reconnect the power cord and press the MODE pad 

until the DRY indicator light is lit.

FAN Mode

Use the FAN mode to provide air circulation and filtering 
without cooling.

To set the FAN mode:

•   Press the FAN pad until the desired indicator light for 

HIGH, LOW, or SLEEP fan speed is lit.

Since fan only settings do not provide cooling, a set 
temperature will not be displayed. After FAN speed has 
been set, the display will change back to show the room 
temperature.

Power Outage Recovery Feature

In the case of a power outage or interruption, the unit will 
automatically re-start in the settings last used after the 
power is restored.

NOTE: If the TIMER was set before the power outage, it 
will need to be reset after power is restored.

The display will always default to show the room temperature.
When the air conditioner is turned on, it will automatically start in the last mode and fan settings selected.

Summary of Contents for APCA10NXMGN1

Page 1: ...a trademark of the General Electric Company Manufactured under trademark license OWNER S MANUAL AND INSTALLATION INSTRUCTIONS AIR CONDITIONER Portable Room 49 7819 02 18 GEA APCA08 APCA10 SAFETY INFOR...

Page 2: ...o every GE Appliances product and we think you will too Among other things registration of your appliance ensures that we can deliver important product information and warranty details when you need t...

Page 3: ...damaged or dropped The air conditioner should be serviced only by qualified service personnel Call an authorized service company for examination repair or adjustment Disconnect power before servicing...

Page 4: ...ng in full cooling mode If room temperature is higher than 77 degrees Fahrenheit fan speed can be adjusted otherwise fan speed is fixed to Low NOTE If the unit is to be used as a dehumidifier do not c...

Page 5: ...er for a 1 24 hour delay until the air conditioner turns off 1 When you use the timer setting button while the unit is operating you can preset a time for the unit to turn off 2 When you use the timer...

Page 6: ...d speed at this setting so a fan speed cannot be set Keep windows and doors closed for the best dehumidifying effects To set the DRY mode Press the MODE pad until the DRY indicator light is lit In the...

Page 7: ...improperly When turning on the air conditioner for the first time after plugging it into an electrical outlet the unit will start in Cooling mode set at 75 F 24 C and at High fan speed The control pa...

Page 8: ...ank has filled with condensed water To Empty the Internal Water Tank 1 Unplug or disconnect power 2 Place a shallow 1 quart or larger pan not included below the lower drain located on the back near th...

Page 9: ...tion procedures as described in these instructions when installing this air conditioner ELECTRICAL REQUIREMENTS Some models require a 115 120 volt AC 60 Hz grounded outlet protected with a 15 amp time...

Page 10: ...ctor Hose Connector Cover 5 Window Panel and Extension Panel 3 1 Air Outlet 2 Control Panel 3 Handle 4 Air Inlet 5 Air Exhaust 6 Caster 7 Power Cord 8 Upper Drain 9 Lower Drain NOTE Please ensure if t...

Page 11: ...he window panel can be installed in a window with a minimum 20 51 cm to a maximum 46 117 cm opening 2 UNPACK AIR CONDITIONER Remove packaging materials Save the carton and the foam packaging for stori...

Page 12: ...the exhaust hose assembly with hose connector 3 onto the window bracket Indoor Indoor 6 COMPLETE INSTALLATION A Plug the power cord into a grounded 3 prong outlet B Press the Reset button on the power...

Page 13: ...rt you of this condition Empty the water tank See Air Conditioner Care Remote control is not working Batteries are dead Replace the batteries Batteries are installed incorrectly Make sure the batterie...

Page 14: ...14 49 7819 Notes NOTES...

Page 15: ...ettingofcircuit breakers Failureduetocorrosiononmodelsnotcorrosion protected Damagetotheproductcausedbyimproperpowersupply voltage accident fire floodsoractsofGod Incidentalorconsequentialdamagecaused...

Page 16: ...GEAppliances com register Parts and Accessories Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes VISA MasterCard and Discover cards are...

Page 17: ...a etiqueta en el costado del acondicionador de aire GE es una marca registrada de General Electric Company Fabricado bajo licencia de marca MANUAL DEL PROPIETARIO Y INSTRUCCIONES DE INSTALACI N INSTRU...

Page 18: ...eemos que usted tambi n Entre otras cosas el registro de su electrodom stico asegura que podamos entregarle informaci n importante del producto y detalles de la garant a cuando los necesite Registre s...

Page 19: ...a para su inspecci n reparaci n o ajuste Desconecte el suministro de energ a antes de darle servicio t cnico Desconecte el suministro de energ a antes de limpiarlo NOTA Si apaga la unidad presionando...

Page 20: ...la unidad sin estar en el modo de refrigeraci n total Si la temperatura del ambiente es superior a 77 grados Fahrenheit la velocidad del ventilador podr ser ajustada de otro modo la velocidad del ven...

Page 21: ...varie selon le mod le 4 Minuterie de mise en marche arr t Pour r gler un d lai de minuterie de 1 24 heures avant la mise l arr t du climatiseur 1 Lorsqu on utilise le bouton de r glage de la minuterie...

Page 22: ...o ser posible configurar la velocidad de la ventilaci n Mantenga las ventanas y puertas cerradas para lograr los mejores efectos de deshumidificaci n Para configurar el modo DRY Seco Presione la tecla...

Page 23: ...emi re fois apr s l avoir branch sur une prise lectrique l appareil d marre en mode de refroidissement r gl sur 75 F 24 C et sur une vitesse de ventilateur le YpH H WDEOHDX GH FRPPDQGH D FKH OD WHPSpU...

Page 24: ...sous l orgies de vidange inf rieur situ l arri re du climatiseur pr s du fond Retirer le capuchon et le bouchon en caoutchouc et vidanger le r servoir d eau R installer le bouchon de vidange et visser...

Page 25: ...laci n Requisitos el ctricos Algunos modelos requieren tomacorrientes de 115 120 voltios de corriente alterna y 60 Hz conectados a tierra protegidos con un fusible de dilataci n de tiempo de 15 amperi...

Page 26: ...e que el drenaje de la salida de agua se encuentre instalado de forma segura antes de su uso 10 Filtro Superior 11 Filtro Inferior 1 2 3 4 5 6 7 8 9 Selladores de gomaespuma 11 10 PARTES INCLUIDAS Apa...

Page 27: ...verture de 20 51 cm minimum 46 117 cm maximum 2 D BALLAGE DU CLIMATISEUR Enlever les mat riaux d emballage Conserver le carton et le polystyr ne d emballage pour entreposer le clima tiseur lorsqu il n...

Page 28: ...r Interior 6 FIN DE L INSTALLATION A Enchufe el cable de corriente en un tomacorriente con conexi n a tierra de 3 patas B Presione el bot n Reset Reiniciar del cable de corriente para asegurarse de qu...

Page 29: ...ns r es correcte ment sens Le climatiseur fonc La temp rature de la pi ce est lev e REMARQUE Durant les journ es tr s chaudes et humides le climatiseur met plus longtemps refroidir la pi ce Lors d une...

Page 30: ...14 49 7819 Notas NOTAS...

Page 31: ...raleza de fuerza mayor Da os incidentales o consecuenciales causados por defectos posibles con este acondicionador de aire Causar da os despu s de la entrega Lo que no est cubierto Empaque su unidad a...

Page 32: ...cesorios Aquellos individuos calificados para realizar el servicio t cnico de sus propios electrodom sticos podr n solicitar el env o de piezas o accesorios directamente a sus hogares se aceptan las t...

Reviews: