– 42 –
Door Closure Mechanisms
Refrigerator Doors
The closure mechanism for each door is attached
to a recess in the bottom of the door with a 1/4-
in. hex-head screw. To access the door closure
mechanism, it is necessary to remove the two T-20
Torx screws and the door stop.
Door Stop
Door Closure Mechanism
The door closure mechanism has a spring loaded
pin that engages the lower door hinge.
Door Alignment
To correctly align doors, adjust front legs until they
are extended to the
fl
oor. If door alignment line does
not match, turn each leveling leg separately until
the leveling matches across both doors.
If the doors remain uneven, turn the adjustable pin
to raise or lower the right door to match the left
door. Use a 1/4-in. Allen wrench to turn the pin.
The right door lower hinge bracket, attached to the
cabinet, has an adjustable pin that allows leveling of
the fresh food doors.
Bottom view of right door lower hinge
Adjustable Pin
Note:
If the left door needs to be raised and an
adjustable pin is not located in the left door hinge
bracket, shims (Part #WR01X11047) are available as
a service part.
1/4-in. Allen Wrench