APPENDIX A – EVENT LOG
NOTE: Your system may not have all of the features listed in this table.
DISPLAY
DESCRIPTION
TXlobat
Transmitter Low Battery
The transmitter has a low battery.
ZN Lost
Zone Lost
A wireless or multiplexed zone device is not reporting to the
control.
Duress
Duress
The control has been armed or disarmed with a Duress code.
Man Fire
Manual Fire
Keypad “Fire” has been activated.
Aux 2
Auxiliary 2
Keypad “Medical” has been activated.
Panic
Panic
Keypad “Panic” has been activated.
KP Tamper
Keypad Tamper
The keypad tamper has been activated.
BoxTamp
Box Tamper
The box tamper circuit has been activated.
AC Fail
AC Fail
AC failure has been detected.
OverCur
Over Current
A short circuit of a power supply has occurred.
Srn Tamp
Siren Tamper
A siren or speaker tamper has been detected.
Tel Flt
Telephone Fault
A telephone fault or tamper has been detected.
Exp Trb
Expansion Trouble
An expansion device or keypad is not reporting to the control.
Log Full
Log Full
The event log is full. Old events will be pushed out as new
ones enter the log.
Open
Open
Reports user number, date, time and partition of opening.
Close
Close
Reports user number, date, time and partition of closing.
Exit Err
Exit Error
Entry/Exit zone was faulted at the instant the exit delay
expired.
Rec Close
Recent Close
An alarm occurred within 5 minutes after the control was
armed.
Autotest
Auto Test
Sending a communicator test at a specified interval.
Start Prog
Start Programming
Local programming is started.
End Prog
End Programming
Local programming is ended.
Start Dnld
Start Download
Download session is started.
End Dnld
End Download
Download session is ended.
Cancel
Cancel
System is disarmed and the Cancel button was pressed
within 5 minutes of an alarm.
Gnd Flt
Ground Fault
A short to ground has been detected.
Man Test
Manual Test
Bell and/or communicator test while system is in disarmed
condition.
Re-exit
Re-Exit
The exit delay has been re-started without disarming the
system.
Output Trip
Output Trip
A trip has occurred on an expander auxiliary output.
Data Lost
Data Lost
Communication of a signal has failed (log only event).
Walk-test
Walk-Test
A zone “Walk-Test” mode has been activated.
End Test
End Test
Test has been ended.
Cross-Trip
Cross Trip
The first zone of a cross zone has been tripped (log only).
Expansion
Event
Expansion Event
An expansion module created an undefined event.
Partial Arm
Partial Arm
Reports a closing in the stay mode.
Listen In
Listen In
A listen in function has been activated.
Service Start
Service Start
Technician is on site.
Service End
Service End
Technician is off site.
Code Entry
Code Entry
A code has been entered.
First Open
First Open
Reports when the first partition is disarmed.
NX-1248E User manual
Page 25
16/04/05