Displays in partitioning master mode
ARMED AND READY STATUS
The LCD screen will display the Armed and Ready status of ALL eight (8) partitions if any or all of the areas
is armed or not ready.
This display is reflecting all 8 areas are Ready, and Area 5 is
disarmed.
NOTE:
If a number is flashing on the armed line,
that area is armed Instant. If a number is flashing on the
ready line, that area is ready to be Force Armed.
If ALL areas are disarmed and ready to arm, this display will
appear on the LCD screen.
ARMING AND DISARMING MULTIPLE PARTITIONS
To arm/disarm multiple partitions, enter a code that has arm/disarm authority for ALL of the partitions to
be armed/disarmed. The following display will appear on the LCD screen.
The numbers on the
top line
represent the disarmed areas
to which this code has access. The numbers on the
bottom
line
represent the areas that are armed.
Refer to the following table for possible conditions :
Armed 1234-678
Ready 12345678
System Ready
Type code to arm
1 2 - 4 5 - 7 8 Disarm
- - 3 - - 6 - -
Arm
LCD DISPLAY FOR AREA
TOP LINE OVER BOTTOM LINE
CONDITION
Blank
Blank
Area Not used or Authorized
Dash (-)
Dash (-)
Area Not Ready
Flashing Area #
Dash (-)
Area Ready to Force Arm
Dash (-)
Flashing Area #
Area Armed Instant
Area #
Dash (-)
Area Disarmed & Ready to Arm
Dash (-)
Area #
Area is Armed
•
To disarm all of these areas, press the
[ ]
up scroll key
•
To arm all of these areas, press the
[ ]
down scroll key
•
To toggle a single area between the armed and disarmed conditions, press [
r
][Area number].
For example: If Area 4 is armed, [
r
] [4] will disarm Area 4. If Area 4 is disarmed, [
r
] [4] will arm it.
•
Press
[
AWAY
],
[
STAY
], or
[
NIGHT
] once to arm all authorized partitions into the corresponding
mode.
•
To control the individual areas, refer to the following section.
NX-1248E User manual
Page 20
16/04/05