![GE Security 60-911 User Manual Download Page 26](http://html.mh-extra.com/html/ge-security/60-911/60-911_user-manual_572131026.webp)
Simon Security System
20
responds with
Sensor # Name open
. Correct the problem by resetting the sensor. If this
condition continues, call your security system dealer
Sensor Tampered
This condition occurs when a sensor is physically tampered with. If the system is armed
an alarm will occur. For example, the cover is taken off of one of the sensors. Your sys-
tem will indicate this condition to you by causing the
SYSTEM STATUS
button to
light. When you press this button, the system responds with,
Sensor # Name tampered.
Correct the problem by resetting the sensor. If this condition continues, call your secu-
rity system dealer.
Option 50 Detected
The panel receiver may be experiencing some interference. The system will call to
notify the central monitoring station about this problem.
Siren 1 or 2 Failure
Call your security system dealer.
System Access Alarm
The panel cover was opened while the system was armed. The system will call the cen-
tral monitoring station to report a tamper alarm.
Testing
As an added safeguard, there are system tests you should do yourself on a regular basis.
It is recommended that you test your system weekly.
Testing Sensors
You can test sensors one at a time to make sure they are sending strong signals to the
panel. You should test the security system at least once a week.
¾
To perform the sensor test:
1. Open the panel Cover.
2. Enter the master access code.
3. Press the
Test
button once. The panel will announce
Sensor
Test
.
4. Press the
DONE
button.
The panel will voice prompt you with a list of your programmed sensors that you need
to test. The panel will start with sensor 1 and announce
Test sensor 1, sensor name.
When you trip a sensor and it communicates successfully it will be removed from the
list. You may trip the sensors in any order. The sensor test has a 4 minute time-out that
resets with each sensor trip.
After all sensors have been successfully tested, the panel will announce
Sensor test
complete, press DONE
.
Press DONE
. The panel will announce
Sensor test ok
.
If any of the sensors did not test successfully and you want to terminate the test,
press
DONE or Cancel
. The panel will announce
Sensor test canceled or failure
. If a sensor
test fails, call your security dealer.
Use the following table to trip devices:
Clearing System Status
Press the
SYSTEM
STATUS
button, listen to the status message, then disarm the
system to clear system status. If the trouble condition was a low CPU battery, per-
form a sensor test. The
SYSTEM STATUS
button should turn off if all trouble condi-
tions have been corrected.
Summary of Contents for 60-911
Page 31: ...Simon Security System 25 ...