GBC 2064
Operation Manual
© 2006 General Binding Corporation
Page 7
FRONT CONTROL GUIDE
Figure 1.
A. Top Temp:
•
When pressed, permits increasing or decreasing of the
top temperature by turning the
MASTER DIAL
and is
indicated on the control panel display. Range is 32°F-
300°F.
B. Bottom Temp:
•
When pressed, permits increasing or decreasing of the
bottom temperature by turning the
MASTER DIAL
and is indicated on the control panel display. Range is
32°F-300°F.
C. Speed:
•
When pressed, permits increasing or decreasing of
speed by turning the
MASTER DIAL
and is indicated
on the control panel display. Range is 1-10.
D. Cooling:
•
When pressed, turns on the cooling fans. When
pressed again, turns off the cooling fans.
E. Meas:
•
When pressed, a number will appear to inform the user
how much film has been ran.
F. Reset:
•
When pressed, will rest your distance.
G. Master Dial:
•
Increases (+) or decreases (-) the numeric value for the selected setting when turned.
H. Stop Button:
•
When pressed, the machine will stop and the rollers will not rotate.
I. Reverse Button:
•
When pressed, the machine will work in reverse mode.
J. Forward Button:
•
When pressed, the machine will be in the forward mode. By pressing this button, the machine will operate in the
forward mode.
K. LCD:
•
The LCD will display the settings the machine is currently set for.
•
Illuminates when the laminator is plugged in and
POWER ON/OFF
is in the on, (I), position. Displays settings for the top
heater, bottom heater, speed, job mode, and ready/wait.
•
TOP: -refers to the Top Main Rollers temperatures setting.
•
BOT: - refers to the Bottom Main Rollers temperatures setting.
•
Mode: -Displays the current Machines Mode. It will read either FWD or REV.
•
Speed: Will display the set speed.
•
PRS: This will show a % of pressure being applied to the Main Rollers.
•
GAP: Will show a % of the gap of the machine.
Figure 1