Additional beep codes provided by optional Intel
Management Modules
In addition to the preceding beep codes, the following additional beep codes are provided
if an Intel Management Module is installed:
LED information
The system board in this server includes LEDs that can assist you in troubleshooting your
system. See the following table for a description of these LEDs and the information they
provide:
Beep Codes
Description
1
Control panel CMOS clear has been initiated
1-5-1-1
Processor failure. Reseat or replace the failed processor.
1-5-2-1
No processor is installed or the CPU 1 socket is empty.
Reseat or replace the failed processor.
1-5-2-3
Processor configuration error or CPU 1 socket is empty.
Reseat or replace the failed processor. In a
two-processor system, make sure the processors are
identical.
1-5-2-4
Front-side bus select configuration error.
1-5-4-2
DC power unexpectedly lost.
1-5-4-3
Chipset control failure.
1-5-4-4
Power control failure.
LED Name
Function
Location
Color
Description
ID
Aid in server
identification
from the back
panel
Front panel and
left back of
system board
Blue
On = Server identification
enabled
System Fault
Visible fault
warning
Front panel and
left back of
system board
Green or
Orange
■
On = No fault
■
Green blink = Degraded
■
Orange = Critical error or
non-recoverable
■
Orange blink = Non critical