4

  

1.

 

Safety

 

Precautions

 

 

Installing

 

the

 

YG

5602/1

 

Gate

 

Opener

 

requires

 

installation

 

of

 

standard

 

110V

 

or

 

230V

 

electrical

 

wiring.

  

This

 

work

 

should

 

only

 

be

 

performed

 

by

 

a

 

trained

 

technician.

  

Mis

wiring

 

could

 

cause

 

personal

 

injury

 

or

 

DEATH.

  

To

 

prevent

 

the

 

risk

 

of

 

electrocution,

 

be

 

sure

 

to

 

turn

 

off

 

all

 

power

 

to

 

the

 

YG

5602/1

 

until

 

installation

 

is

 

complete.

 

 

 

Please

 

keep

 

hands,

 

fingers

 

and

 

loose

 

clothing

 

away

 

from

 

moving

 

parts

 

as

 

they

 

may

 

be

 

dragged

 

into

 

moving

 

parts.

 

 

The

 

gate

 

may

 

move

 

at

 

any

 

time.

 

Ensure

 

all

 

persons

 

are

 

clear

 

of

 

the

 

gate

 

when

 

it

 

is

 

moving

 

to

 

avoid

 

the

 

risk

 

of

 

injury.

 

Do

 

not

 

touch

 

the

 

gate

 

while

 

it

 

is

 

in

 

operation.

 

Do

 

not

 

attempt

 

to

 

go

 

through

 

the

 

gate

 

while

 

it

 

is

 

still

 

in

 

motion.

 

This

 

opener

 

is

 

intended

 

for

 

vehicular

 

use

 

only.

 

 

Do

 

not

 

allow

 

children

 

or

 

pets

 

near

 

your

 

gate.

 

Keep

 

the

 

remote

 

controls

 

away

 

from

 

children.

  

Place

 

controls

 

where

 

they

 

cannot

 

be

 

accessed

 

by

 

reaching

 

through

 

the

 

gate.

 

 

To

 

avoid

 

electric

 

shock,

 

unplug

 

unit

 

before

 

opening

 

case.

 

 

Make

 

sure

 

the

 

battery

 

inside

 

the

 

opener

 

is

 

charged

 

fully

 

before

 

using.

 

 

Before

 

installation,

 

the

 

clutch

 

should

 

be

 

unlocked.

 

 

The

 

auto

reverse

 

function

 

must

 

be

 

checked

 

during

 

installation

 

to

 

ensure

 

that

 

the

 

gate

 

can

 

auto

reverse

 

in

 

the

 

event

 

of

 

obstruction,

 

and

 

it

 

should

 

be

 

inspected

 

regularly.

 

 

The

 

automatic

 

gate

 

opener

 

must

 

be

 

grounded.

 

 

Install

 

the

 

gate

 

opener

 

on

 

the

 

inside

 

of

 

the

 

property;

 

DO

 

NOT

 

install

 

it

 

on

 

the

 

outside

 

of

 

the

 

property

 

where

 

the

 

public

 

has

 

access

 

to

 

it!

 

 

Additional

 

safety

 

equipment

 

such

 

as

 

photoelectric

 

sensors,

 

safety

 

edges,

 

roller

 

guards

 

and

 

warning

 

signs

 

must

 

be

 

installed

 

to

 

prevent

 

injury.

 

 

In

 

the

 

event

 

of

 

power

 

failure,

 

an

 

emergency

 

release

 

key

 

allows

 

you

 

to

 

operate

 

the

 

gate

 

manually.

 

 

Please

 

erase

 

and

 

reset

 

the

 

code

 

after

 

installing

 

the

 

opener.

 

 

The

 

gate

 

opener

 

should

 

be

 

installed

 

by

 

a

 

qualified

 

technician;

 

otherwise,

 

serious

 

personal

 

injury

 

or

 

property

 

damage

 

may

 

occur.

 

 

For

 

service,

 

call

 

an

 

experienced

 

technician.

  

Do

 

not

 

in

 

any

 

way

 

modify

 

the

 

components

 

of

 

the

 

automated

 

system;

 

otherwise

 

serious

 

personal

 

injury

 

or

 

property

 

damage

 

may

 

occur.

 

We

 

do

 

not

 

accept

 

responsibility

 

for

 

damage

 

or

 

injury

 

resulting

 

from

 

the

 

installation

 

of

 

this

 

opener.

 

Summary of Contents for YG-5602/1U/E

Page 1: ...YG 5602 1U E SWINGING GATE OPENER OWNER S MANUAL...

Page 2: ...1 2011 Gatekeeper Ltd P O Box 752 Lacey s Spring AL 35754 http www gatekeeperltd com...

Page 3: ...d 13 7 Stopper and Latch Installation 14 8 Electrical Installation 16 8 1 Connecting the AC Power 16 8 2 Wiring the Battery see Fig 7b 17 8 3 Wiring the Actuators 17 8 4 First Time Activation Test 18...

Page 4: ...3 THIS PAGE INTENTIONALLY LEFT BLANK...

Page 5: ...ke sure the battery inside the opener is charged fully before using Before installation the clutch should be unlocked The auto reverse function must be checked during installation to ensure that the g...

Page 6: ...ng code technology prevents thieves from guessing your remote code Manual key release design for emergency purposes Supports Keypad interface and Magnetic Loop Detectors simultaneously 3 Specification...

Page 7: ...ave not already done so wire a waterproof outlet near the gate following proper safety standards for your area If you are not experienced with this type of wiring or if your area requires it hire a pr...

Page 8: ...Through beam type infra red photo sensor 5 Electric Latch with Keylock 6 Mounting bracket 7 Antenna 8 Control box 9 Cotter Pin 10 Clevis Pin 11 Keys and manual key lock 12 Remote key Not shown in pict...

Page 9: ...ator to your gate No Description Quantity Single Dual 1 Actuator 1 2 2 Nest Pin 1 2 3 Fastener Screw 1 2 4 L Mounting Bracket 2 4 5 Bar Mounting Bracket 1 2 6 Nut for Bolt 2 4 7 Bolt 2 4 8 Release Key...

Page 10: ...ents 1 Actuator Maximum Direct Force 1400N 315 lbs 2 Actuator Maximum Power Consumption 12V at 6A 72W 3 Duty Cycle 50 30mm 1 2 T Mounting Bracket 150mm 5 9 20mm 78 20mm 78 20mm 78 20mm 78 8mm 31 15mm...

Page 11: ...moothly before installing the YG 5602 swinging gate opener The gate must be plumb level and move freely More detailed instructions on page 6 Sec 5 Site Preparation Conduit In order to protect the wire...

Page 12: ...ace of the mounting post and the opener is mounted on the face 90 degrees from it Below are schematics of both push to open and pull to open configurations A PULL TO OPEN INWARD Use this setup to make...

Page 13: ...hould always be inside the property so that it cannot be tampered with from the outside Initially mount the actuators on the gate so that the gate is open Figure 4 Opening Angle A cm A inch B cm B inc...

Page 14: ...m should always be inside the property so that it cannot be tampered with from the outside Initially mount the actuators on the gate so that the gate is open Figure 5 Opening Angle A cm A inch B cm B...

Page 15: ...ectrical Latch OPTIONAL 3 Install the Electrical Latch and the Slave Gate Stop on the gate as shown in the diagram 4 Install the L Bar on the opposite gate 5 Install Stopper 1 stops gate in closed pos...

Page 16: ...al Maintenance Regularly verify that the gate swings freely Add grease to the gate as directed by the manufacturer of the gate Check that wiring and other electrical parts are weather proof Keep opene...

Page 17: ...e the ground usually green to the terminal on the left Wire the hot usually black wire to the middle terminal Wire the neutral usually white wire to the terminal on the right Verify that all electrica...

Page 18: ...ing light Gate is waiting for auto close execution Lamp fixed light 7 sec without gate movement Gate is in a waiting mode since the photocell has been covered by obstacle during the gate closing or op...

Page 19: ...need to reverse the motor operating direction No matter which method of installation is used pull to open or push to open the first operation should be defined as gate closing phase during the proced...

Page 20: ...main button one black one on the left of the transmitter it will then be memorized up to 15 different transmitters can be memorized After the LED light is turned off the receiver module will go back t...

Page 21: ...entation for details The keypad device can be obtained through your dealer To find a dealer go to www gatekeeperltd com dealers 10 2 Loop detector A magnetic loop detector detects vehicles that are wi...

Page 22: ...photocell remove the short circuit wire between Terminals 14 and 15 Attach the normally closed wire to 14 and the other common normally closed wire to 15 COM Attach the 12VDC power for the photocell t...

Page 23: ...gate operation J4 11 use with 12 Keypad Pushbutton for the single gate operation J4 12 Logical and Power Ground for external devices J4 13 Positive Supply 12V DC J4 14 15 Photo sensor contacts must b...

Page 24: ...VDC Max current 3A J3 Terminal block 7 8 Connect to the flashing light 12VDC Max power 15W J4 Terminal block 13 ve 12 ve Connect to the external receiver board for the 12 V DC Positive and Gnd Negativ...

Page 25: ...24 11 1 Visual Guide for Wiring...

Page 26: ...hen an obstruction is placed in its path then the setting may be too high Start with just above the minimum value and tune it to use the minimum setting for which the gate will function WARNING Do not...

Page 27: ...ON Auto close On waiting time 12 seconds Cancel auto close function Move the fourth and fifth DIP switches to the off position in order to disable the auto close feature 14 Additional Features LIGHT...

Page 28: ...c If any command transmitter keypad or photocell or other abnormal case interrupts the leaf s motion before it moves to the end of travel the gate can only be operated with slow down speed for the res...

Page 29: ...to make sure that the battery and transformer J7 J8 is well connected The gate stopped during the operation opening or closing 1 Check to make sure that the Reset switch is on and that the reset swit...

Page 30: ...t stop immediately when it reaches the end of travel 1 Adjust the VR1 to decrease the over current limit Flashing light doesn t work Check the wiring of the flashing light to make sure that it is wel...

Page 31: ...implied Gatekeeper Ltd specifically disclaims any and all implied warranties of merchantability or fitness for a particular purpose It is the purchaser s sole and exclusive responsibility to determine...

Page 32: ...erltd com For updated versions of the manual see http www gatekeeperltd com For Additional Remotes Infrared Photo Cells or Parts please contact your dealer To locate a dealer please visit us at www ga...