background image

21

  

10.3

 ‐ 

Safe

 

guard

 

(Infrared

 

device

 

or

 

Photocell)

 

It

 

is

 

recommended

 

that

 

the

 

installer

 

install

 

the

 

included

 

infrared

 

photocell

 

for

 

additional

 

safety.

  

Photocells

 

work

 

by

 

inhibiting

 

the

 

movement

 

of

 

the

 

gate

 

if

 

the

 

beam

 

is

 

broken.

  

Infrared

 

safety

 

devices

 

may

 

be

 

required

 

by

 

law

 

in

 

some

 

areas.

  

 

If

 

the

 

infrared

 

beam

 

is

 

broken

 

during

 

closing,

 

the

 

gates

 

will

 

reverse

 

and

 

open

 

immediately.

 

During

 

opening,

 

the

 

beeper

 

will

 

ring.

  

 

Infrared

 

photocells

 

come

 

in

 

active

 

and

 

passive

 

varieties.

  

Active

 

photocells

 

require

 

power

 

on

 

both

 

sides

 

of

 

the

 

driveway,

 

whereas

 

passive

 

photocells

 

employ

 

a

 

reflector

 

plate

 

so

 

that

 

power

 

is

 

only

 

required

 

on

 

one

 

side

 

of

 

the

 

driveway.

  

Most

 

photocells

 

will

 

provide

 

DC

 

power

 

input

 

wires

 

+

 

and

 ‐

,

 

and

 

2

 

normally

 

closed

 

switch

 

wires.

  

To

 

install

 

the

 

photocell,

 

remove

 

the

 

short

 

circuit

 

wire

 

between

 

Terminals

 

(14)

 

and

 

(15).

  

Attach

 

the

 

normally

 

closed

 

wire

 

to

 

(14)

 

and

 

the

 

other

 

common

 

normally

 

closed

 

wire

 

to

 

(15)

 

(COM).

  

Attach

 

the

 

+12VDC

 

power

 

for

 

the

 

photocell

 

to

 

(13)

 

and

 

the

 

–DC

 

power

 

to

 

(15).

   

 

The

 

signal

 

wires

 

are

 

not

 

polarized

 

so

 

they

 

can

 

be

 

interchanged

 

without

 

issue,

 

but

 

the

 

power

 

wires

 

must

 

be

 

wired

 

correctly

 

to

 

prevent

 

damage.

  

Consult

 

your

 

device

 

manufacturer’s

 

documentation

 

for

 

details.

   

 

In

 

the

 

closing

 

phase,

 

if

 

an

 

obstacle

 

breaks

 

the

 

infrared

 

beam

 

of

 

the

 

photocell,

 

then

 

the

 

gate

 

will

 

stop

 

and

 

reverse

 

after

 

approx

 

3

 

seconds.

  

In

 

the

 

opening

 

phase,

 

the

 

function

 

of

 

the

 

photo

 

sensor

 

can

 

be

 

selected

 

between

 

active

 

or

 

passive.

  

If

 

the

 

photo

 

sensor

 

is

 

set

 

for

 

the

 

active

 

mode,

 

and

 

the

 

infrared

 

beam

 

is

 

broken,

 

then

 

the

 

system

 

will

 

stop

 

and

 

wait

 

for

 

a

 

new

 

command.

  

 

The

 

infrared

 

device

 

is

 

included

 

in

 

your

 

kit,

 

additional

 

devices

 

can

 

be

 

obtained

 

through

 

your

 

dealer.

 

To

 

find

 

a

 

dealer,

 

go

 

to

 

www.gatekeeperltd.com/dealers

 

Summary of Contents for YG-5602/1U/E

Page 1: ...YG 5602 1U E SWINGING GATE OPENER OWNER S MANUAL...

Page 2: ...1 2011 Gatekeeper Ltd P O Box 752 Lacey s Spring AL 35754 http www gatekeeperltd com...

Page 3: ...d 13 7 Stopper and Latch Installation 14 8 Electrical Installation 16 8 1 Connecting the AC Power 16 8 2 Wiring the Battery see Fig 7b 17 8 3 Wiring the Actuators 17 8 4 First Time Activation Test 18...

Page 4: ...3 THIS PAGE INTENTIONALLY LEFT BLANK...

Page 5: ...ke sure the battery inside the opener is charged fully before using Before installation the clutch should be unlocked The auto reverse function must be checked during installation to ensure that the g...

Page 6: ...ng code technology prevents thieves from guessing your remote code Manual key release design for emergency purposes Supports Keypad interface and Magnetic Loop Detectors simultaneously 3 Specification...

Page 7: ...ave not already done so wire a waterproof outlet near the gate following proper safety standards for your area If you are not experienced with this type of wiring or if your area requires it hire a pr...

Page 8: ...Through beam type infra red photo sensor 5 Electric Latch with Keylock 6 Mounting bracket 7 Antenna 8 Control box 9 Cotter Pin 10 Clevis Pin 11 Keys and manual key lock 12 Remote key Not shown in pict...

Page 9: ...ator to your gate No Description Quantity Single Dual 1 Actuator 1 2 2 Nest Pin 1 2 3 Fastener Screw 1 2 4 L Mounting Bracket 2 4 5 Bar Mounting Bracket 1 2 6 Nut for Bolt 2 4 7 Bolt 2 4 8 Release Key...

Page 10: ...ents 1 Actuator Maximum Direct Force 1400N 315 lbs 2 Actuator Maximum Power Consumption 12V at 6A 72W 3 Duty Cycle 50 30mm 1 2 T Mounting Bracket 150mm 5 9 20mm 78 20mm 78 20mm 78 20mm 78 8mm 31 15mm...

Page 11: ...moothly before installing the YG 5602 swinging gate opener The gate must be plumb level and move freely More detailed instructions on page 6 Sec 5 Site Preparation Conduit In order to protect the wire...

Page 12: ...ace of the mounting post and the opener is mounted on the face 90 degrees from it Below are schematics of both push to open and pull to open configurations A PULL TO OPEN INWARD Use this setup to make...

Page 13: ...hould always be inside the property so that it cannot be tampered with from the outside Initially mount the actuators on the gate so that the gate is open Figure 4 Opening Angle A cm A inch B cm B inc...

Page 14: ...m should always be inside the property so that it cannot be tampered with from the outside Initially mount the actuators on the gate so that the gate is open Figure 5 Opening Angle A cm A inch B cm B...

Page 15: ...ectrical Latch OPTIONAL 3 Install the Electrical Latch and the Slave Gate Stop on the gate as shown in the diagram 4 Install the L Bar on the opposite gate 5 Install Stopper 1 stops gate in closed pos...

Page 16: ...al Maintenance Regularly verify that the gate swings freely Add grease to the gate as directed by the manufacturer of the gate Check that wiring and other electrical parts are weather proof Keep opene...

Page 17: ...e the ground usually green to the terminal on the left Wire the hot usually black wire to the middle terminal Wire the neutral usually white wire to the terminal on the right Verify that all electrica...

Page 18: ...ing light Gate is waiting for auto close execution Lamp fixed light 7 sec without gate movement Gate is in a waiting mode since the photocell has been covered by obstacle during the gate closing or op...

Page 19: ...need to reverse the motor operating direction No matter which method of installation is used pull to open or push to open the first operation should be defined as gate closing phase during the proced...

Page 20: ...main button one black one on the left of the transmitter it will then be memorized up to 15 different transmitters can be memorized After the LED light is turned off the receiver module will go back t...

Page 21: ...entation for details The keypad device can be obtained through your dealer To find a dealer go to www gatekeeperltd com dealers 10 2 Loop detector A magnetic loop detector detects vehicles that are wi...

Page 22: ...photocell remove the short circuit wire between Terminals 14 and 15 Attach the normally closed wire to 14 and the other common normally closed wire to 15 COM Attach the 12VDC power for the photocell t...

Page 23: ...gate operation J4 11 use with 12 Keypad Pushbutton for the single gate operation J4 12 Logical and Power Ground for external devices J4 13 Positive Supply 12V DC J4 14 15 Photo sensor contacts must b...

Page 24: ...VDC Max current 3A J3 Terminal block 7 8 Connect to the flashing light 12VDC Max power 15W J4 Terminal block 13 ve 12 ve Connect to the external receiver board for the 12 V DC Positive and Gnd Negativ...

Page 25: ...24 11 1 Visual Guide for Wiring...

Page 26: ...hen an obstruction is placed in its path then the setting may be too high Start with just above the minimum value and tune it to use the minimum setting for which the gate will function WARNING Do not...

Page 27: ...ON Auto close On waiting time 12 seconds Cancel auto close function Move the fourth and fifth DIP switches to the off position in order to disable the auto close feature 14 Additional Features LIGHT...

Page 28: ...c If any command transmitter keypad or photocell or other abnormal case interrupts the leaf s motion before it moves to the end of travel the gate can only be operated with slow down speed for the res...

Page 29: ...to make sure that the battery and transformer J7 J8 is well connected The gate stopped during the operation opening or closing 1 Check to make sure that the Reset switch is on and that the reset swit...

Page 30: ...t stop immediately when it reaches the end of travel 1 Adjust the VR1 to decrease the over current limit Flashing light doesn t work Check the wiring of the flashing light to make sure that it is wel...

Page 31: ...implied Gatekeeper Ltd specifically disclaims any and all implied warranties of merchantability or fitness for a particular purpose It is the purchaser s sole and exclusive responsibility to determine...

Page 32: ...erltd com For updated versions of the manual see http www gatekeeperltd com For Additional Remotes Infrared Photo Cells or Parts please contact your dealer To locate a dealer please visit us at www ga...

Reviews: