BUS, network and USB connections are located on the underside of the InductWarm
®
140 unit:
If a certain number of InductWarm
®
140 units should be operated within a network, one chosen unit of the
network must be connected to an external control panel and connected via BUS cable to any other unit within
the network. When the ON/OFF button of the external control panel is pushed, the connected unit becomes the
“master” of the network. All other units become “slaves”.
Every 3 seconds, the master unit sends information to the slave units. When running in network mode, the units
can only be operated on the same power level. It is not possible to control each unit individually.
Note: Valid “AutoPowerOff“ time for the entire network is the time set
within the “master” device (default 600s).
To run the units in a network, each device must have an individual device address!
When ordering
the devices, please specify how the devices are to be operated.
If there is no dish detected on any of the units in the network, all units will automatically go into standby
mode after 20 seconds. In network mode, dish detection is not shown by flashing power level buttons. Up to
16 InductWarm
®
140 units can be linked with a BUS network cable.
Summary of Contents for InductWarm 140
Page 1: ...1 ...
Page 12: ...12 ...
Page 13: ...13 Mindestabstand bei Einbau mehrerer Module ...
Page 21: ...21 ...
Page 28: ...28 ...
Page 29: ...29 Minimum distance when installing numerous units ...
Page 37: ...37 ...
Page 38: ...38 ...
Page 45: ...45 Instructions de montage pour un appareil ...
Page 46: ...46 Disposition de plusieurs appareils les uns à côté des autres ...
Page 55: ...55 ...