E n g l i s h
|
6
Erroneous connection could lead to overheating of the terminal board which could lead to blowout
and electric shock.
Check that all the connections are tight before connecting the device to the mains.
PE = Yellow/Green: “EARTH”
protection conductor.
N = Blue:
neutral conductor.
L = Brown, Grey, Black:
live conductors
Check there is no static discharge between live and earth. Check the limit switch continuity
between the external casing and the earth wire of the mains. It is advised to use a multi tester to
carry out these operations.
CABLE SUBSTITUTION
This must be carried out by a qualified authorised technician. The earth wire must always be
yellow green.
WARNING: the yellow/green voltage wires in the earth cable must be 3cm longer than the
others.
Proceed as follows to connect the power supply wire to the terminal board:
•
( A1 ) Loosen the tops of the cable gland and open the bottom part of the back of the
appliance by loosening the screws.
•
( A3 ) Loosen the terminal screws and feed the cable conductors through. Take out the
old cable from the cable gland.
•
( A2 ) Feed the new cable through the cable gland. Connect the new cable’s conductors
to the terminal following the connection diagram on the label at the lower part of the back of the
appliance. Only connect what is indicated inserting the copper bridge and the electricity cable