PROBLEM SOLVING
PROBLEM
PROBLEM CASUES
SOLUTION
When the main power switch is in
the "I" position, the lights on the
control panel will not light up.
1) The machine was incorrectly
connected.
2) The plug was not correctly inserted
in the socket.
3) There is an unconnected wire inside
the plug.
4) A lamp of the control panel is blown.
5) The emergency stop button has not
been released.
1, 2, 3) Check the electrical connections.
4) Replace the light.
5) Release the emergency stop button by
turning it clockwise.
When the start button is pressed, the
machine will not turn on.
1) The mobile bowl cover is open.
2) There is a fault with the safety
microswitches.
1) Close the mobile
2) Replace the microswitches.
Continuing noise.
1) The bearings are no longer efficient
.
1) Check the bearings and replace them
if necessary.
The spiral stops.
1) The drive belts are loose.
2) The drive belts are worn.
1) Tighten the straps.
2) Replace the belts.
The bowl stops.
1) The drive belts are loose.
2) The drive belts are worn.
1) Tighten the straps.
2) Replace the belts.