28
WARNINGS
DISABLED
EXIT
4. Once the correct setting is shown, press the MODE
button.
Save Changes?
YES
NO Cancel
5. Press the MODE button with YES highlighted to save the
new warning alarm setting.
3.5.6.2 Adjust warning alarm levels
1. Enter the Alarm Menu as described above in section 3.5.1.
ALARMS MENU
CUSTOM LATCH
DEFAULT TEMPERATURE
WARNINGS
EXIT
2. Use the navigation arrows to highlight WARNINGS and
press the MODE button. The warning alarm settings
screen will then be shown.
WARNINGS
ENABLE
ADJUST
TIMEOUT
EXIT
3. Use the up and down navigation arrows to highlight
ADJUST and press the MODE button. The High Warning
Adjust screen will then be shown.
HIGH WARNING ADJUST
CH
4
0.2
%/Vol
CO
17 ppm
H
2
S 5.0
ppm
EXIT
4. Use the up and down navigation arrows to highlight the
alarm for adjustment and press the MODE button.
WARNING ADJUSTMENT
CO
17
ppm
5. Use the up and down navigation arrows to make the
adjustment. Once the warning alarm level has been
adjusted as needed, press the MODE button to enter the
new setting.
WARNING ADJUSTMENT
CO
25
ppm
Save Changes?
YES
NO Cancel
6. Press the MODE button with YES highlighted to save the
new warning alarm setting.
3.5.6.3 Timeout
adjustment
The warning alarm can be silenced for a designated amount of
time by pressing the MODE button. The timeout adjustment
controls the length of time that the warning alarm will remain
silent before it will again become audible. The timeout can be
set to any whole minute interval between 1 and 60 minutes, or
it can be disabled by setting the interval to 0.
Note: The warning alarm timeout function disables the
audible alarm only. The Cannonball3 display will still
indicate that a warning alarm is present.
To adjust the timeout interval:
1. Enter the Alarm Menu as described above in section 3.5.1.