Installation
Before Installation
● Before cutting into any bench tops, ensure the minimum clearances to
walls,
adjacent surfaces and overhead surfaces required by the relevant gas appliance
installation code (see above) will comply. Dimensions are specified in
millimeters (mm)
Overhead cupboards and range hood = 650 mm.
Side and rear clearance = 200 mm to any burner edge.
Overhead exhaust/ceiling fan = 750 mm
Horizontal surfaces adjacent the hob = less than or equal to the hob height.
Ensure there is sufficient clearance to fit the regulator and/or flexible hose
connection with the hotplate in the installed position.
Before the appliance is installed into the cabinet,please make sure any transit
protection is removed.
When you have installed the hob, make sure that
● The GPO(general purpose outlet) must always be in an accessible position.
● The supply connection point, test point and natural gas regulator adjust ment
screw (for Natural gas installation) are accessible for testing and/or adjustment
with the hotplate in the installed position.
Technical Specifications
Product
Dimensions
(h x w x d)mm
Model
GH60SSC
GH30SFC
100 x 580 x 500
100x290x500
552 x 470
266 x
478
5.32Kg
8.99Kg
220-240V/50Hz
220-240V/50Hz
0.5W
GH12SFC
100x290x500 266 x 478
5.64Kg
220-240V/50Hz 0.5W
0.5W
GH90SF
100 x 860 x 500 827 x 470 11.37Kg 220-240V/50Hz 0.5W
Net
weight
Cut-out
Size
(w x d)mm
Rated
Input
Power
Electrical
Connection