3-4.1. General
This paragraph shows an example of the mapping of a site. This procedure consists of the following
steps:
•
Locating and mapping all objects of the site.
•
Assigning logical identifications (Id.) to the devices.
•
Assigning the Ethernet and Serial addresses of devices linked to the network.
•
Obtaining a functional and physical Map of the devices in the site.
3-4.2. Locating all objects of the site
•
Locate the roads around the site.
•
Locate the islands and their dispensers.
•
Locate the fuel tanks.
•
Locate the intended position of the CFN PLUS.
•
Draw a basic map of the site with all the objects.
3-4.3. Assigning Logical IDs
3-4.3.1. To each fuel tank
•
Assign the tank sequential number (coordinated with the station manager).
•
Assign its fuel code and name.
•
Assign its TLG Probe (AP) Id.
3-4.3.2. To each Dispenser Unit
•
Assign an id. to every dispenser name and Pump Server.
•
Assign an id. to every dispenser pump (P).
•
Assign an id. to every pump CPU addresses if any.
•
Assign an id. to its nozzles (N).
•
Assign to each nozzle the tank (T) Id. to whom it is linked.
3-4.3.3. To CFN PLUS
•
Assign the CFN PLUS its id. after installation on a flat surface.
3-4.4. Mapping
•
Draw a map of the site.
•
Use the map methodology and Ids. For later setup configuration.