background image

MDE-4652F Atlas® 9800 Electronics Field Installation Instructions · September 2019

Page 1

Introduction

Purpose

This manual provides instructions for installing the Atlas

® 

9800 Electronics.

Intended Users

This manual is intended for Gasboy

®

-trained and certified Authorized Service Contractors 

(ASCs).

Table of Contents

Topic

Page

Introduction

1

Important Safety Information

3

Atlas 9800 Parts

5

Accessing Electronic Components

9

Installing Atlas 9800 Power Supply Assembly (M15579A001)

10

Installing Atlas 9800 CPU Board (M06333KXXXX)

12

Installing Atlas 9800 Pulse-out I/F with EM Totalizer Drive Board (M06587A001)

18

Loading New CPU Software

20

Required Tools

A Phillips

®

 screwdriver is required for installing the Atlas

 

9800 Electronics.

Parts List

The following table lists the parts required for installing the Atlas 9800 Electronics:

Item #

Description

Part Number

Quantity

1

Printed Circuit Assembly (PCA), Central Processing 
Unit (CPU) Board

M06333KXXXX

1

2

Kit, 115 VAC Power Supply to replace C06397 or 
M07588A001

M12421K00X**

1

3

Atlas 9800 Power Supply Assembly

M15579A001

1

4

Kit, 230 VAC Power Supply to replace C06489 or 
M07588A003

M12422K00X**

1

MDE-4652F

Atlas

®

 9800 Electronics Field Installation Instructions

September 2019

Summary of Contents for Atlas 9800

Page 1: ...oard M06333KXXXX 12 Installing Atlas 9800 Pulse out I F with EM Totalizer Drive Board M06587A001 18 Loading New CPU Software 20 Required Tools A Phillips screwdriver is required for installing the Atl...

Page 2: ...tro mechanical FMS Fuel Management System GOLD Gilbarco Online Documentation J box Junction Box LED Light Emitting Diode NEC National Electric Code NFPA National Fire Protection Association OSHA Occup...

Page 3: ...ure to install inspect maintain or service this equipment in accordance with these codes regulations and standards may lead to legal citations with penalties or affect the safe use and operation of th...

Page 4: ...so on Age of victim for example baby teenager middle age elderly Whether or not victim has received first aid for example stopped bleeding by pressure and so on Whether or not a victim has vomited fo...

Page 5: ...ll Pulse out I F Boards C06425 C06746 M05158A001 M05158A002 M05158A003 M06587A001 Replaces 9800 CPU Boards C06391 C06392 C06393 C06394 C06500 C06501 C06502 C06503 M05346A001 M05346A002 M05346A003 M053...

Page 6: ...800 Power Supply Assembly M15579A001 Features of the Atlas 9800 power supply are as follows Required for M06333 CPU Boards refer Figure 1 on page 5 Compatible with the following 9800 CPU Boards C06391...

Page 7: ...ard refer Figure 1 on page 5 Serial EEPROM Board Software Type Pump Type M06656K001 9800K 9852K 9853K M06656K002 9850 9850A 9850Q 9850K M06656K003 9840K 9840K M06656K004 9800Q 9852A Q 9853A Q 9822A Q...

Page 8: ...up to two dual channel outputs per hose Compatible with 9800 CPU Boards C06391 C06392 C06393 C06394 C06500 C06501 C06502 C06503 M05346A001 M05346A002 M05346A003 M05346A004 and M06333KXXXX Can be used...

Page 9: ...in place of previous 9800 RS 485 I F Board C06389 and M05248A001 Required for Atlas PRIME Figure 5 K Pump RS 485 with Totalizer Accessing Electronic Components Always remove AC power from the pump dis...

Page 10: ...If the existing supply is not a M07588A00X or M15579A001 or if it is not working it must be replaced For the correct replacement part number refer to Atlas 9800 Power Supply Assembly M15579A001 on pag...

Page 11: ...pply on the standoffs Ensure that the P1 connector is closest to the CPU board and P3 connector is away from the CPU If the pump model is 9822 or 9823 the P1 connector is closest to the pump handle as...

Page 12: ...must be replaced Use the M08218K001 Kit to install the new bracket 4 If the pump dispenser has a RS 485 or pulse out I F board remove the screws that secure the I F board and disconnect it from the e...

Page 13: ...The delay time must be set to 0 seconds for suction pumps Delay Time JP3 JP4 0 seconds Jumpered Jumpered 4 seconds Jumpered Open 5 seconds Open Jumpered 6 seconds Open Open JP5 Hose Pressurization For...

Page 14: ...10 Check these switches and change if required Switch settings must be changed with the power to the pump dispenser Off CPU board only reads new switch settings during power up Note A switch in the c...

Page 15: ...Open Closed Open None Closed Open Open None Open Open Open Maximum pulse output rate that can be achieved depends on the model of the pump dispenser and the unit of measure Pulse output rate of 1000...

Page 16: ...bled Closed Disabled Open SW2 5 and SW2 6 Unit of Measure Selection These two switches set the unit of measure US gallons liters or Imperial gallons that the pump dispenser will use to meter fuel Unit...

Page 17: ...3 the second set is the software type for example 9800 1 and the third set is the firmware version for example 01008 Ensure that the displayed software type is correct for the pump dispenser model tha...

Page 18: ...onfigured for Dual Channel Single Hose Pulse out I F or Single Channel Dual Single Hose Pulse out I F the P3 Connector is not connected When configured for Dual Channel Dual Hose Pulse out I F the P3...

Page 19: ...Hose Pulse out I F Pulse Side 1 Side 1B Output Side 1A Output Side 1A Return Side 1A Return Figure 8 Single Channel Dual Single Hose Pulse out I F Pulse Side 1 Pulse Side 2 Side 1 Output Side 2 Outpu...

Page 20: ...iddle of the CPU board 5 Connect the DC cable to the P1 connector on the power supply Connect AC power to the pump dispenser 6 At this point on the Serial EEPROM board assembly the green PWR and yello...

Page 21: ...onds to the 9800K Software 9852K 9853K 9862KX 9872KX 9800 3 Corresponds to the 9800K Software 9862KX 9872KX 9840 1 Corresponds to the 9840Q Software 9840A 9840Q 9840 2 Corresponds to the 9840K Softwar...

Page 22: ...Protection Association Phillips is a registered trademark of Phillips Screw Company TopKAT is a trademark of Gasboy International 2019 Gilbarco Inc 7300 West Friendly Avenue Post Office Box 22087 Gre...