Installing Atlas 9800 Pulse-out I/F with EM Totalizer Drive Board (M06587A001)
Page 18
MDE-4652F Atlas® 9800 Electronics Field Installation Instructions · September 2019
Installing Atlas 9800 Pulse-out I/F with EM Totalizer Drive
Board (M06587A001)
JP1, JP2, and JP3
This board assembly can be configured for use in one of the following pump/dispenser
configurations:
• Dual Channel, Single Hose Pulse-out I/F (refer
)
• Single Channel, Dual/Single Hose Pulse-out I/F (refer
• Dual Channel, Dual Hose Pulse-out I/F (refer
The following table shows the jumper settings and wires to connect to in the Junction Box (J-
box), based on the configuration.
Check JP1 - JP3 jumpers and change them, if required. The jumper settings must be changed
only when the power to the pump/dispenser is removed, to protect the circuit that they are
connected to.
Default configuration is Single Channel, Dual/Single Hose Pulse-out I/F. When configured for
Dual Channel, Single Hose Pulse-out I/F, or Single Channel, Dual/Single Hose Pulse-out I/F,
the P3 Connector is not connected.
When configured for Dual Channel, Dual Hose Pulse-out I/F, the P3 connector is used.
Jumper Settings
Single Channel, Dual/Single
Hose Pulse-out I/F
(Default Setting)
Dual Channel, Single Hose
Pulse-out I/F
Dual Channel, Dual Hose
Pulse-out I/F
Wire Color JP1 Position 1
JP2 Position 1
JP3 Open
JP1 Position 2
JP2 Position 2
JP3 Open
JP1 Position 2
JP2 Position 2
JP3 Jumpered
Red
Pulse out Side 1
Pulse out Side1A
Pulse out Side 1A
Green
Pulse out Side 2
Pulse out Side1B
Pulse out Side 1B
White
Common Return
Side 1A Return
Side 1A Return
Black
No Connection
Side 1B Return
Side 1B Return
Brown
No Connection
No Connection
Pulse out Side 2A
Orange
No Connection
No Connection
Pulse out Side 2B
Yellow
No Connection
No Connection
Side 2A Return
Gray
No Connection
No Connection
Side 2B Return
JP4 and JP5
When this board is used in a model A or Q pump/dispenser or 9850K, jumpers JP4 and JP5 are
set to the Q/A position. When this board is used for all other K models except 9850K, these
jumpers must be in the K position.