MDE-4652F Atlas® 9800 Electronics Field Installation Instructions · September 2019

Page 13

Installing Atlas 9800 CPU Board (M06333KXXXX)

JP2 - Mode

This jumper selects the mode in which the pump/dispenser operates. Set the mode to “Online” 
if the pump/dispenser communicates to a controlling system (for example, Gasboy TopKAT 
PLUS or CFN PLUS System). Set the mode to “Standalone” for all other configurations [for 
example, Gasboy Series 1000 Fuel Management System (FMS) or no controlling system].

Mode

JP2

Standalone Jumpered

Online

Open

JP3, JP4 - Leak Detect Delay

These jumpers select the delay time used by leak detectors in Submersible Turbine Pump 
(STP) applications. The delay time is the period between the activation of the submersible 
pump and the activation of the slow flow valve. The delay time must be set according to the 
type of leak detector installed on the STP to allow for a normal leak test for each transaction. 
The delay time must be set to 0 seconds for suction pumps.

Delay Time JP3

JP4

0 seconds

Jumpered

Jumpered

4 seconds

Jumpered

Open

5 seconds

Open

Jumpered

6 seconds

Open

Open

JP5 - Hose Pressurization

For US Gallons (always in Hose Pressurization mode), this jumper is ignored. This jumper is 
used to determine if hose pressurization is used. If enabled, the slow flow valve is opened 
before reset is complete, to allow the hose to be pressurized before fuel dispensing begins.

Pressurization JP5

Enabled

Jumpered

Disabled

Open

JP6 - Authorization

This jumper allows activation or non-activation of the pump/dispenser from an external source 
(for example, an FMS). When jumpered, a 115/230 VAC signal must be present on the Control 
Feed/authorization line (refer to the wiring diagram for your model pump/dispenser) for pump 
activation to occur (required setting for Gasboy Series 1000). When open, the Control Feed 
line signal is ignored (required setting for Standalone mode).

Authorization JP6

Enabled

Jumpered

Disabled

Open

Note: For JP6 Authorization, in Standalone mode, the authorization signal must be present to 

activate the pump.

Summary of Contents for Atlas 9800

Page 1: ...oard M06333KXXXX 12 Installing Atlas 9800 Pulse out I F with EM Totalizer Drive Board M06587A001 18 Loading New CPU Software 20 Required Tools A Phillips screwdriver is required for installing the Atl...

Page 2: ...tro mechanical FMS Fuel Management System GOLD Gilbarco Online Documentation J box Junction Box LED Light Emitting Diode NEC National Electric Code NFPA National Fire Protection Association OSHA Occup...

Page 3: ...ure to install inspect maintain or service this equipment in accordance with these codes regulations and standards may lead to legal citations with penalties or affect the safe use and operation of th...

Page 4: ...so on Age of victim for example baby teenager middle age elderly Whether or not victim has received first aid for example stopped bleeding by pressure and so on Whether or not a victim has vomited fo...

Page 5: ...ll Pulse out I F Boards C06425 C06746 M05158A001 M05158A002 M05158A003 M06587A001 Replaces 9800 CPU Boards C06391 C06392 C06393 C06394 C06500 C06501 C06502 C06503 M05346A001 M05346A002 M05346A003 M053...

Page 6: ...800 Power Supply Assembly M15579A001 Features of the Atlas 9800 power supply are as follows Required for M06333 CPU Boards refer Figure 1 on page 5 Compatible with the following 9800 CPU Boards C06391...

Page 7: ...ard refer Figure 1 on page 5 Serial EEPROM Board Software Type Pump Type M06656K001 9800K 9852K 9853K M06656K002 9850 9850A 9850Q 9850K M06656K003 9840K 9840K M06656K004 9800Q 9852A Q 9853A Q 9822A Q...

Page 8: ...up to two dual channel outputs per hose Compatible with 9800 CPU Boards C06391 C06392 C06393 C06394 C06500 C06501 C06502 C06503 M05346A001 M05346A002 M05346A003 M05346A004 and M06333KXXXX Can be used...

Page 9: ...in place of previous 9800 RS 485 I F Board C06389 and M05248A001 Required for Atlas PRIME Figure 5 K Pump RS 485 with Totalizer Accessing Electronic Components Always remove AC power from the pump dis...

Page 10: ...If the existing supply is not a M07588A00X or M15579A001 or if it is not working it must be replaced For the correct replacement part number refer to Atlas 9800 Power Supply Assembly M15579A001 on pag...

Page 11: ...pply on the standoffs Ensure that the P1 connector is closest to the CPU board and P3 connector is away from the CPU If the pump model is 9822 or 9823 the P1 connector is closest to the pump handle as...

Page 12: ...must be replaced Use the M08218K001 Kit to install the new bracket 4 If the pump dispenser has a RS 485 or pulse out I F board remove the screws that secure the I F board and disconnect it from the e...

Page 13: ...The delay time must be set to 0 seconds for suction pumps Delay Time JP3 JP4 0 seconds Jumpered Jumpered 4 seconds Jumpered Open 5 seconds Open Jumpered 6 seconds Open Open JP5 Hose Pressurization For...

Page 14: ...10 Check these switches and change if required Switch settings must be changed with the power to the pump dispenser Off CPU board only reads new switch settings during power up Note A switch in the c...

Page 15: ...Open Closed Open None Closed Open Open None Open Open Open Maximum pulse output rate that can be achieved depends on the model of the pump dispenser and the unit of measure Pulse output rate of 1000...

Page 16: ...bled Closed Disabled Open SW2 5 and SW2 6 Unit of Measure Selection These two switches set the unit of measure US gallons liters or Imperial gallons that the pump dispenser will use to meter fuel Unit...

Page 17: ...3 the second set is the software type for example 9800 1 and the third set is the firmware version for example 01008 Ensure that the displayed software type is correct for the pump dispenser model tha...

Page 18: ...onfigured for Dual Channel Single Hose Pulse out I F or Single Channel Dual Single Hose Pulse out I F the P3 Connector is not connected When configured for Dual Channel Dual Hose Pulse out I F the P3...

Page 19: ...Hose Pulse out I F Pulse Side 1 Side 1B Output Side 1A Output Side 1A Return Side 1A Return Figure 8 Single Channel Dual Single Hose Pulse out I F Pulse Side 1 Pulse Side 2 Side 1 Output Side 2 Outpu...

Page 20: ...iddle of the CPU board 5 Connect the DC cable to the P1 connector on the power supply Connect AC power to the pump dispenser 6 At this point on the Serial EEPROM board assembly the green PWR and yello...

Page 21: ...onds to the 9800K Software 9852K 9853K 9862KX 9872KX 9800 3 Corresponds to the 9800K Software 9862KX 9872KX 9840 1 Corresponds to the 9840Q Software 9840A 9840Q 9840 2 Corresponds to the 9840K Softwar...

Page 22: ...Protection Association Phillips is a registered trademark of Phillips Screw Company TopKAT is a trademark of Gasboy International 2019 Gilbarco Inc 7300 West Friendly Avenue Post Office Box 22087 Gre...

Reviews: