Installing Atlas 9800 CPU Board (M06333KXXXX)
Page 16
MDE-4652F Atlas® 9800 Electronics Field Installation Instructions · September 2019
Leading zeros are always suppressed in the tens and hundreds place to the left of the decimal
point. In Standalone mode, positions to the right of the decimal point are displayed based on
the pulse output rate and unit of measure selected.
Pulse Rate
Gallons - US or Imperial Liters and/or 9850
1:1
XXX
XXXX
10:1
XXX.X
XXXX.X
100:1
XXX.XX
XXXX.XX
250:1
XXX.XXX
XXXX.XX
500:1
XXX.XXX
XXXX.XX
Timeout Switch (if JP2 is Jumpered)
When the pump/dispenser is in the Standalone mode, including Pulse-out I/F configurations, it
will turn off an active hose outlet if it does not detect input pulses for 4 minutes and 15
seconds.
Timeout
SW2-4
Enabled
Closed
Disabled
Open
SW2-5 and SW2-6 - Unit of Measure Selection
These two switches set the unit of measure (US gallons, liters, or Imperial gallons) that the
pump/dispenser will use to meter fuel.
Unit of Measure
SW2-5
SW2-6
US Gallons
Closed
Closed
Liters
Open
Closed
Imperial Gallons
Closed
Open
NOT USED (default US Gallons) Open
Open
SW2-7 - EM Totalizer Enable
This switch is only used on K model pumps/dispensers (excluding the 9850K model). When
closed (“On”), it enables the pump/dispenser to drive electro-mechanical totalizers used on
some K models pump. On A and Q models, this switch must be set to disabled (open).
EM Totalizer
SW2-7
Enabled
Closed
Disabled
Open
SW2-8 - BDM Enable
This switch must be open for normal operation.
SW2-9 - Software Load Enable
This switch must be open for normal operation. When this switch is closed, it enables loading
the new software (refer to
on
SW2-10
This switch is not used (or close it to ground input).