40
MAGNASCANNER CS 5000
OWNERS MANUAL
' 2000 GARRETT METAL DETECTORS, INC.
PN 11674XX
Revised
11.5.
REMOTE CONTROL (OPTIONAL)
A complete remote console with all control func-
tions that are available on the overhead panel is
available for monitoring and controlling func-
tions of the Magnascanner CS 5000 from a
location apart from the archway.
This remote console is connected to the over-
head unit with telephone-type cable and RJ 45
connectors which can be easily concealed
behind overhead panels or in 1/2-inch conduit.
The remote control receives its power from the
main detector unit.
Pressing a touchpad on the remote console
achieves the same result as pressing the same
touchpad on the overhead panel, except for the
VOLUME
and
TONE
adjustment.
Regulating alarm volume and tone must be
done separately at the remote console and at
each unit it controls. This enables the audio to
be set separately at the required levels for the
console and archway. A 50-foot cable is stan-
dard, but custom lengths are available.
11.5.1.
INSTALLATION
¥ With power disconnected locate archway and console in their desired locations;
¥
Locate connecting wire and protect from tampering or vandalism, as necessary;
¥
Plug the wire into the rear of the console;
¥
Open the Access Door of the detection unit;
¥
Remove three (3) screws that hold the controller cover;
¥ Plug the wire into the Circuit Board connector as shown on Page 23;
¥
Replace covers and connect to power.