4.
SELF-DIAGNOSTIC TESTS
The Garrett Magnascanner CS 5000 LCD panel provides valuable information concern-
ing the operation of this unit and the self-diagnostic program of which it is capable.
4.1.
OPERATING INFORMATION
When the unit is placed into operation from the Standby Mode, the following informa-
tion is reported:
1.
Serial Number
of the unit will be displayed.
2.
Software Version
of the unit will be displayed.
3.
50 Hz
or
60 Hz
will be displayed, indicating current status, if the unit is connected
to power line AC.
4.
MASTER
or
SLAVE
will be displayed, indicating current status.
5. CHANNEL designation will be displayed, indicating current status.
6. Program and Sensitivity levels (
PROG SENS 160
will be displayed initially), indi-
cating current status.
4.1.1.
SELF-TEST INFORMATION
After the sequence listed above is completed, as well as any time the system power is
connected or any time the
OPERATE SELF-TEST
touchpad is pressed, a system self-
test procedure will be performed. The following information will be displayed on the
Display Panel, as necessary.
SELF-TEST will be displayed as the unit tests itself auto-
matically. If any of the following six errors are detected, they will be displayed as
shown below:
Example:
SELF-TEST...3..4 (Indicates that both Error 3 and Error 4 are occurring.)
4.1.2.
CORRECTIVE ACTIONS
4.1.2.1.
Error 1:
Power failure
Check line voltage and externally connected devices.
4.1.2.2.
Error 2:
IR Emitter failure
Check connector to Panel A.
4.1.2.3.
Error 3:
IR Receiver failure
Check connector to Panel B; check for blockage of IR beam at waist level of unit.
4.1.2.4.
Error 4:
Receiver Balance problem
Check for large metal objects near panels.
4.1.2.5.
Error 5:
Transmit Energy out of range
Check all connectors; check for very large object near Panel A.
4.1.2.6.
Error 6:
No Line Sync
If unit is in Slave Mode, check synchronization cable; otherwise, verify that the unit is