9.
MAINTENANCE & REPAIR
9.1.
PERIODIC MAINTENANCE
Periodic maintenance of the equipment requires only inspection for loose or damaged
parts and cleaning of the exterior surfaces.
¥
Open the access door of the Detection Unit and check that all connectors are
snapped securely and that all screws and nuts are in place.
¥
Inspect the windows of the IR Sensor to make certain they are not blocked in any way.
¥
Check to make certain that the eight (8) screws that attach the Crosspiece and Detec
tion Unit to the Panels are in place and tight.
¥
Check to make certain that the archway sits flat on the floor and does not sway or
rock.
¥
If the power cord or cable to remote devices are at floor level, check for frayed or
broken wires. Replace immediately.
¥
Clean exterior surfaces with mild soap and water only. If a solvent is necessary for
heavy cleaning, use only denatured alcohol.
Test the detector daily, or whenever the environment changes.
9.2.
REPAIR
There are no user-adjustable controls inside the unit.
Should the equipment ever fail to perform properly, contact the seller for the name of
the nearest field service representative, or contact the factory.
Because the equipment is of modular design, repairs can often be made through
replacement of these plug-in modules. An illustrated parts list follows for your conve-
nience.
If problems are site-related, see Page 7 or contact the factory for assistance. Many
times these problems may be resolved through the adjustment of the equipment or
through relocation of the equipment or surrounding objects.
9.3.
MODULE REPLACEMENT
The system is built as a series of modules, each of which can be easily removed and
replaced. These modules are tested and calibrated independently, and there is no need
for adjustment of any other electronic assembly when a module is replaced.
It is
necessary
to test the system carefully to verify operation and the suitability of the
product after any component replacement.
21
MAGNASCANNER CS 5000
OWNER S MANUAL
' 2000 GARRETT METAL DETECTORS, INC.
4/30/00
PN 1530100
Revised