Internal AC input protection
Inrush current limitation per phase
I
INRUSH LIMIT
< 3 x I
AC
Max
Rated Current Fuse (per module)
I
BREAK
Rating
80 A
typ
Breaking capacity of fuses
I
BREAK
Capacity
80 000 A
Max
Max earth leakage current
I
LEAKAGE
< 3,5 mA
Max
Emergency button connection
Yes
Overvoltage (IEC60664-1)
OVC III
Insulation protection Class (IEC60664-1)
Class I
TECHNICAL SPECIFICATION
Internal DC Output
Output voltage
V
DC_
max
530 V
DC
Max
V
DC_
min 150 V Min
Output current
I
DC
_max
65A
(1)(2)
Max
I
DC
_min
1,5 A
Min
Max Output Power
P
OUT
24 kW
Max
Output connector (charging station side)
Permanent mounting
Car Plug connector
Plug #1
CCS
Plug #2
CHAdeMO
Output cable length
-
3,50
Meters
AC output for GARO ATLE CCS + C AC only
AC output
AC Output voltage
V
AC_
nom
400 V
± 10%
AC Output current
I
AC
_max
32 A
Max
Max Output Power
P
OUT
22 kVA
Max
Car Plug socket
Plug #3
AC type 2 socket
Type of connection
Case “B” connection (mode3)
Detachable cable
General & dimensions
External dimensions (mm)
H x W x D
860 x 507 x 250 mm (CCS or CHAdeMO)
1225 x 507 x 250 mm (CCS + CHAdeMO)
Weight (without cable, or bracket)
kg
66 kg (CCS or CHAdeMO) Max
93 kg (CCS + CHAdeMO)
Max
Type of installation
Mounting on a wall or on a pedestal with proper fixation point
Fixation points
8 screws
Protection type (EN60529)
IP
IP55
Cooling systems
Heatsink with forced air flow by fans IP55 without air filter
Noise (1m, all direction)
Db(A)
65dbA (1m)
5