GNS 400W Series Installation Manual
Page 4-17
190-00356-08
Rev. G
4.7.2.3
COM AUDIO, VOR/ILS AUDIO
Pin Name
Connector
Pin
I/O
500 COM AUDIO HI
P4002
7
Out
500 COM AUDIO LO
P4002
19
Out
500 VOR/ILS AUDIO HI
P4006
16
Out
500 VOR/ILS AUDIO LO
P4006
17
Out
500 COM AUDIO and 500 VOR/ILS AUDIO each supply 100 mW into a 500 load. These are
balanced outputs and the LO output must be connected.
500 COM AUDIO is the summation of the COM receiver audio, COM sidetone audio, and
INTERCOM MIC audio.
4.7.2.4
DISCRETE INPUTS
Pin Name
Connector
Pin
I/O
TRANSMIT INTERLOCK
P4002
14
In
COM REMOTE TRANSFER
P4002
15
In
VLOC REMOTE TRANSFER
P4006
28
In
These inputs are considered active if either the voltage to ground is < 1.9 V or the resistance to ground is
< 375 . These inputs are considered inactive if the voltage to ground is 11-33 VDC.
COM REMOTE TRANSFER and VLOC REMOTE TRANSFER are momentary inputs.
4.7.3
COM/VOR/ILS Audio Configuration
None.
4.7.4
COM/VOR/ILS Audio Calibration and Checkout
Refer to Section 5.3.12 for the COM calibration.
4.7.5
COM/VOR/ILS Audio Interconnect
Refer to Figure H-19 for the audio panel interconnect.
Summary of Contents for GPS 400W
Page 1: ...190 00356 08 August 2012 Rev G...
Page 2: ......
Page 125: ...GNS 400W Series Installation Manual Page 6 1 190 00356 08 Rev G 6 RESERVED...
Page 133: ...GNS 400W Series Installation Manual Page B 1 190 00356 08 Rev G Appendix B RESERVED...
Page 135: ...GNS 400W Series Installation Manual Page C 1 190 00356 08 Rev G Appendix C RESERVED...
Page 155: ...GNS 400W Series Installation Manual Page G 1 190 00356 08 Rev G Appendix G RESERVED...
Page 179: ...GNS 400W Series Installation Manual Page H 23 190 00356 08 Rev G Figure H 14 Not Used...
Page 211: ......
Page 212: ......