Page 5-36
GNS 400W Series Installation Manual
Rev. G
190-00356-08
5.5.4
VHF NAV Checkout (GNS 430W)
Press the CDI key to select VLOC mode (indicated by a white VLOC in the lower left corner of the
display). Check the VOR reception with ground equipment, operating VOT or VOR, and verify audio
and Morse code ID functions (if possible). Tune a Localizer frequency and verify the CDI needle and
NAV flag, and VDI needle and GS flag operation.
5.5.5
VHF COM Checkout (GNC 420W/GNS 430W)
5.5.5.1
Antenna Check
If desired, the antenna VSWR can be checked using an inline wattmeter in the antenna coax using
frequencies near both ends of the band. The VSWR should be < 2:1, and is not to exceed 3:1. A VSWR
of 2:1 will cause a drop in output power of approximately 12%, and 3:1 causes approximately a 26%
drop.
5.5.5.2
Receiver/Transmitter Operation
Tune the unit to a local VHF frequency and verify the receiver output produces a clear and
understandable audio output. Verify the transmitter functions properly by contacting another station and
getting a report of reliable communications.
5.5.6
Interface Checkout
This section describes checks that must be carried out to verify that systems interfacing to the
400W Series unit are communicating properly. Only those interfaces that are connected to the
400W Series unit must be verified.
5.5.6.1
Honeywell (Bendix/King) EFS40/50 Interface Check
If a Honeywell EFS40/50 has been connected to 400W Series unit the interface should be verified as
described in this section.
1.
Cycle power to the first 400W Series unit and acknowledge the prompts until it gets to the self
test page (see Section 5.5.1).
2.
Ensure that GPS1 data is displayed by pressing the ―1-2‖ key on the EFS40/50 control panel.
3.
While the 400W Series unit is displaying the self test page, verify that the EFS40/50 is
displaying data from the GPS source. Note that vertical deviation will not be displayed.
Course Deviation: Half-scale left deviation, TO indication, flag pulled
Active Waypoint: GARMN
Vertical Deviation: Half-scale up deviation (Only if installation is set up to display GPS
vertical deviation)
4.
On the 400W Series unit verify that an OBS value is displayed (and not dashed out).
5.
Using a VOR test set verify that the CDI deviation on the EFS40/50 is displayed correctly.
6.
Cycle power to the second 400W Series unit and acknowledge the prompts until it gets to the self
test page (see Section 5.5.1).
7.
Switch to GPS2 data by pressing the ―1-2‖ key on the EFS40/50 control panel and repeat steps 3
through 5 with the second 400W Series unit.
5.5.6.2
Sandel SN3308 Interface Check
If a Sandel SN3308 EHSI has been connected to the 400W Series unit, the interface should be verified as
described in one of the following sections, as appropriate for the installation.
Summary of Contents for GPS 400W
Page 1: ...190 00356 08 August 2012 Rev G...
Page 2: ......
Page 125: ...GNS 400W Series Installation Manual Page 6 1 190 00356 08 Rev G 6 RESERVED...
Page 133: ...GNS 400W Series Installation Manual Page B 1 190 00356 08 Rev G Appendix B RESERVED...
Page 135: ...GNS 400W Series Installation Manual Page C 1 190 00356 08 Rev G Appendix C RESERVED...
Page 155: ...GNS 400W Series Installation Manual Page G 1 190 00356 08 Rev G Appendix G RESERVED...
Page 179: ...GNS 400W Series Installation Manual Page H 23 190 00356 08 Rev G Figure H 14 Not Used...
Page 211: ......