GNS 400W Series Installation Manual
Page 5-37
190-00356-08
Rev. G
5.5.6.2.1
One 400W Series Unit / One SN3308
1.
Cycle power to the 400W Series unit and acknowledge the prompts until it gets to the self test
page (see Section 5.5.1).
2.
Ensure that the SN3308 is receiving valid heading.
NOTE
The Vertical Deviation Indication will not be displayed unless the SN3308 is receiving
valid heading.
3.
While the 400W Series unit is displaying the self test page, verify that the SN3308 is displaying
the following data from the GPS source.
Course Deviation: Half-scale left deviation, TO indication, flag pulled
Vertical Deviation: Half-scale up deviation, flag pulled
Active Waypoint: GARMN
4.
On the 400W Series unit verify that an OBS value is displayed (and not dashed out).
5.
Acknowledge the self test on the 400W Series unit by pressing the ENT key.
6.
Select VLOC on the 400W Series unit and verify that the SN3308 displays NAV 1 or
NAV 2 (depending on what navigation source the 400W is).
7.
Using a VOR test set verify that the CDI deviation on the SN3308 is displayed correctly.
Summary of Contents for GPS 400W
Page 1: ...190 00356 08 August 2012 Rev G...
Page 2: ......
Page 125: ...GNS 400W Series Installation Manual Page 6 1 190 00356 08 Rev G 6 RESERVED...
Page 133: ...GNS 400W Series Installation Manual Page B 1 190 00356 08 Rev G Appendix B RESERVED...
Page 135: ...GNS 400W Series Installation Manual Page C 1 190 00356 08 Rev G Appendix C RESERVED...
Page 155: ...GNS 400W Series Installation Manual Page G 1 190 00356 08 Rev G Appendix G RESERVED...
Page 179: ...GNS 400W Series Installation Manual Page H 23 190 00356 08 Rev G Figure H 14 Not Used...
Page 211: ......
Page 212: ......