GNS 400W Series Installation Manual
Page 5-29
190-00356-08
Rev. G
5.4
Ground Checks (Configuration Mode)
5.4.1
Main Indicator (Analog Only)
NOTE
If the 400W Series unit is interfaced to an electronic HSI and the main indicator analog
output is not used, this check is not required.
If the 400W Series unit is interfaced to an analog indicator on the main CDI/OBS, perform the following
steps:
1.
Go to the MAIN CDI/OBS CONFIG page.
2.
Verify correct operation of the lateral deviation, flag and TO/FROM flag using the
corresponding selections.
3.
Verify correct operation of the vertical deviation and flag using the corresponding selections.
4.
Verify correct operation of the OBS knob using the SELECTED COURSE display. At 30°
increments around the OBS card, ensure that the indicated value is within 2° of the value set on
the indicator.
5.4.2
VOR/ILS Indicator (GNS 430W Only)
If the GNS 430W unit is interfaced to an analog indicator on the VOR/ILS Indicator output, perform the
following steps:
1.
Go to the VOR/LOC/GS CDI configuration page.
2.
Verify correct operation of the lateral deviation, flag and TO/FROM flag using the
corresponding selections.
3.
Verify correct operation of the vertical deviation and flag using the corresponding selections.
5.4.3
Discrete Inputs and Annunciator Outputs Checkout
If the 400W Series unit is connected to external annunciators/systems or external switches, perform the
following steps:
1.
Go to the MAIN DISCRETE INPUTS page.
2.
For each external switch that is connected, exercise the switch and use the EXTERNAL
SWITCH STATE section to verify that the input is functioning correctly.
3.
Go to the MAIN DISCRETE OUTPUTS page.
4.
For each annunciator output that is connected to an external system or annunciator, toggle the
output ON (corresponding box is filled/green) and OFF (corresponding box is not filled/blue)
using the DISCRETE TOGGLE field. Verify that the appropriate external annunciator
illuminates when the output is set to ON and extinguishes when the output is set to OFF. If the
output is not connected to an annunciator but provides an input to another system, verify that the
other system receives the signal.
Summary of Contents for GPS 400W
Page 1: ...190 00356 08 August 2012 Rev G...
Page 2: ......
Page 125: ...GNS 400W Series Installation Manual Page 6 1 190 00356 08 Rev G 6 RESERVED...
Page 133: ...GNS 400W Series Installation Manual Page B 1 190 00356 08 Rev G Appendix B RESERVED...
Page 135: ...GNS 400W Series Installation Manual Page C 1 190 00356 08 Rev G Appendix C RESERVED...
Page 155: ...GNS 400W Series Installation Manual Page G 1 190 00356 08 Rev G Appendix G RESERVED...
Page 179: ...GNS 400W Series Installation Manual Page H 23 190 00356 08 Rev G Figure H 14 Not Used...
Page 211: ......
Page 212: ......