Page 1-2
500 SERIES INSTALLATION MANUAL
Rev Q
190-00181-02
1.3 TECHNICAL
SPECIFICATIONS
The conditions and tests required for TSO approval of this article are minimum performance standards. It
is the responsibility of those installing this article either on or within a specific type or class of aircraft to
determine that the aircraft installation conditions are within the TSO standards. TSO articles must have
separate approval for installation in an aircraft. The article may be installed only in compliance with 14
CFR part 43 or the applicable airworthiness requirements. For TSO compliance, see Appendix A.
1.3.1 Physical
Characteristics
Bezel Height
4.58 in. (116 mm)
Bezel Width
6.25 in. (159 mm)
Rack Height (Dimple-to-dimple)
4.60 in. (117 mm)
Rack Width
6.32 in. (161 mm)
Depth Behind Panel with
Connectors (Measured from
face of aircraft panel to rear of
connector backshells)
11.00 in. (279 mm)
GPS 500 Weight (Unit only)
5.7 lbs. (2.59 kg)
GPS 500 Weight (Installed with
rack and connectors)
7.2 lbs. (3.27 kg)
GNS 530 Weight (Unit only)
7.0 lbs. (3.18 kg)
GNS 530 Weight (Installed with
rack and connectors)
8.7 lbs. (3.95 kg)
1.3.2 General
Specifications
Operating Temperature Range
-20
q
C to +55
q
C. For more details see Environmental
Qualification Form.
Humidity
95% non-condensing
Altitude Range
-1,500 ft to 50,000 ft
Input Voltage Range
GPS 500 (011-00562-00, -10)
GNS 530 (011-00550-10, -30)
11 to 33 Vdc
Input Voltage Range
GNS 530 (011-00550-00)
22 to 33 Vdc
Input Voltage Range
GNS 530A (011-00835-00, -10)
28 Vdc
Power Requirements
GPS 500
800 mA @ 27.5 Vdc (maximum)
1.6 A @ 13.8 Vdc (maximum)
Power Requirements—P5001
(GNS 530 Main Connector)
1.8 A @ 27.5 Vdc (maximum)
3.6 A @ 13.75 Vdc (maximum)
Power Requirements—P5002
(COM Connector)
GNS 530 (011-00550-00)
GNS 530A (011-00835-00, -10)
15 mA @ 27.5 Vdc (not transmitting);
3.0 A @ 27.5 Vdc (transmitting)
Power Requirements—P5002
(COM Connector)
GNS 530 (011-00550-10)
15 mA @ 27.5 Vdc (not transmitting);
3.0 A @ 27.5 Vdc (transmitting)
15 mA @ 13.75 Vdc (not transmitting);
6.0 A @ 13.75 Vdc (transmitting)
Superflag Power Requirements
500 mA max. Per superflag output @ 27.5 Vdc
.
1.0 A max. @ 27.5 Vdc on P5001 (Main Superflags).
1.0 A max. @ 27.5 Vdc on P5006 (VOR/LOC, G/S
Superflags).
Software
RTCA DO-178B level C
Environmental Testing
RTCA DO-160C.
For more details see Environmental Qualification Forms.
Summary of Contents for GNS 530
Page 84: ...Page A 4 500 SERIES INSTALLATION MANUAL Rev Q 190 00181 02 This page intentionally left blank ...
Page 86: ...Page B 2 500 SERIES INSTALLATION MANUAL Rev Q 190 00181 02 ...
Page 87: ...500 SERIES INSTALLATION MANUAL Page B 3 190 00181 02 Rev Q ...
Page 88: ...Page B 4 500 SERIES INSTALLATION MANUAL Rev Q 190 00181 02 ...
Page 89: ...500 SERIES INSTALLATION MANUAL Page B 5 190 00181 02 Rev Q ...
Page 90: ...Page B 6 500 SERIES INSTALLATION MANUAL Rev Q 190 00181 02 ...
Page 91: ...500 SERIES INSTALLATION MANUAL Page B 7 190 00181 02 Rev Q ...
Page 92: ...Page B 8 500 SERIES INSTALLATION MANUAL Rev Q 190 00181 02 ...
Page 93: ...500 SERIES INSTALLATION MANUAL Page B 9 190 00181 02 Rev Q ...