Page 5-22
500 SERIES INSTALLATION MANUAL
Rev Q
190-00181-02
5.3.3 Signal Acquisition Test
Upon approval of the Instrument Panel Self-test Page, the Satellite Status Page is displayed. If the unit is
unable to acquire satellites, relocate the aircraft away from obstructions which might be shading GPS
reception. If the situation does not improve, check the GPS antenna installation.
Once GPS position information is available, use the DIRECT-TO key to activate the navigation function to
a nearby airport, NAVAID, or intersection. Ensure that any connected equipment is transmitting and/or
receiving data from the 500 Series unit and is functioning properly (see the Pilot’s Guide for more
information on the direct-to function).
5.3.4 Deviation & Flags Check
5.3.4.1 Analog Deviation & Flags
The analog deviation (LEFT/RIGHT and UP/DOWN), TO/FROM, and FLAG (lateral and vertical) outputs
to a CDI or HSI should be verified in flight with potential sources of electrical noise such as autopilot,
flaps, gear, heater blowers, etc. operating. Lateral deviation and flags may be checked with either GPS or
VOR/ILS, and vertical deviation and flags must be checked with Glideslope. Verify that the flags are
hidden at the correct times, and that the flag is in view at the correct times.
5.3.4.2 EHSI Deviation Scaling (Only if HSI/CDI is driven by the 500 Series unit via serial
data)
With the 500 Series unit locked onto a GPS fix, activate an OBS waypoint about 20 nautical miles from the
present position.
1. With 5.0 nautical mile CDI sensitivity, adjust the OBS course for approximately half-scale
deflection on the 500 Series unit’s Default Navigation page. Verify that the EHSI displays a
similar half-scale deviation.
2. Repeat step 1 with 1.0 nautical mile CDI sensitivity. The CDI sensitivity may be manually set on
the AUX SETUP page, using the “CDI / ALARMS” menu item.
3. Repeat step 1 with 0.3 nautical mile CDI sensitivity.
5.3.5 Crossfill Check (Only if dual units installed with RS-232 crossfill connected)
Turn on both 400/500 Series units in the aircraft. For each 400/500 Series unit:
1. Select the first AUX page (titled “FLIGHT PLANNING”).
2. Select “CROSSFILL”.
3. Verify that the displayed status is “Ready”. If “Not Available” is displayed, there may be an RS-
232 wiring problem between the two 400/500 Series units.
Summary of Contents for GNS 530
Page 84: ...Page A 4 500 SERIES INSTALLATION MANUAL Rev Q 190 00181 02 This page intentionally left blank ...
Page 86: ...Page B 2 500 SERIES INSTALLATION MANUAL Rev Q 190 00181 02 ...
Page 87: ...500 SERIES INSTALLATION MANUAL Page B 3 190 00181 02 Rev Q ...
Page 88: ...Page B 4 500 SERIES INSTALLATION MANUAL Rev Q 190 00181 02 ...
Page 89: ...500 SERIES INSTALLATION MANUAL Page B 5 190 00181 02 Rev Q ...
Page 90: ...Page B 6 500 SERIES INSTALLATION MANUAL Rev Q 190 00181 02 ...
Page 91: ...500 SERIES INSTALLATION MANUAL Page B 7 190 00181 02 Rev Q ...
Page 92: ...Page B 8 500 SERIES INSTALLATION MANUAL Rev Q 190 00181 02 ...
Page 93: ...500 SERIES INSTALLATION MANUAL Page B 9 190 00181 02 Rev Q ...
Page 94: ...Page B 10 500 SERIES INSTALLATION MANUAL Rev Q 190 00181 02 ...