Page 4-20
500 SERIES INSTALLATION MANUAL
Rev Q
190-00181-02
4.8.2.4 Flag
Pin Name
Connector
Pin
I/O
VOR/LOC +FLAG
P5006
3
Out
VOR/LOC -FLAG (VOR/LOC COMMON)
P5006
4
Out
GLIDFLAG
P5006
30
Out
GLIDDOWN/-FLAG (GLIDESLOPE
COMMON)
P5006 31
Out
The Flag output is capable of driving up to three 1000
:
meter loads. When valid information is present
(Flag OUT OF VIEW) the Flag output is 375 ±80 mVdc
.
When invalid information is present (Flag IN
VIEW) the Flag output is 0 ±25 mVdc
.
4.8.2.5 OBS
Pin Name
Connector
Pin
I/O
VOR OBS ROTOR C
P5006
9
Out
VOR OBS ROTOR H (GROUND)
P5006
10
Out
VOR OBS STATOR D
P5006
13
In
VOR OBS STATOR F
P5006
12
In
VOR OBS STATOR E/G (VOR/LOC
COMMON)
P5006 11
Out
VOR OBS ROTOR C and H are a buffered 500 Hz output that is intended to drive the OBS rotors. VOR
OBS STATOR D and VOR OBS STATOR F are each phase and amplitude shifted version of the VOR
ROTOR C output. Each pair is intended to read one of the two windings of the indicator’s OBS stator.
4.8.2.6 VOR/LOC COMPOSITE
Pin Name
Connector
Pin
I/O
VOR/LOC COMPOSITE OUT
P5006
8
Out
With a Standard VOR Test Signal applied, VOR/LOC COMPOSITE OUT is 0.5 ± 0.1 V
RMS
into a 10 k
:
load. With a Standard Localizer Centering Test Signal applied, VOR/LOC COMPOSITE OUT is 0.350
±0.05 Vrms into a 10 k
:
load.
4.8.2.7 ILS ENERGIZE
Pin Name
Connector
Pin
I/O
ILS ENERGIZE
P5006
29
Out
The driver output voltage is not more than 1.0 V when sinking 20 mA. The maximum off state leakage
current with respect to GND is less than 10
P
A.
4.8.3 VOR/ILS Indicator Configuration
Refer to section 5.2.12 for the VOR/LOC/GS configuration.
4.8.4 VOR/ILS Indicator Calibration and Checkout
Refer to sections 5.2.12 and 5.3.8 for the VOR/LOC/GS checkout.
4.8.5 VOR/ILS Indicator Interconnect
Refer to Figure F-27 on page F-55 for the VOR/ILS indicator interconnect.
Summary of Contents for GNS 530
Page 84: ...Page A 4 500 SERIES INSTALLATION MANUAL Rev Q 190 00181 02 This page intentionally left blank ...
Page 86: ...Page B 2 500 SERIES INSTALLATION MANUAL Rev Q 190 00181 02 ...
Page 87: ...500 SERIES INSTALLATION MANUAL Page B 3 190 00181 02 Rev Q ...
Page 88: ...Page B 4 500 SERIES INSTALLATION MANUAL Rev Q 190 00181 02 ...
Page 89: ...500 SERIES INSTALLATION MANUAL Page B 5 190 00181 02 Rev Q ...
Page 90: ...Page B 6 500 SERIES INSTALLATION MANUAL Rev Q 190 00181 02 ...
Page 91: ...500 SERIES INSTALLATION MANUAL Page B 7 190 00181 02 Rev Q ...
Page 92: ...Page B 8 500 SERIES INSTALLATION MANUAL Rev Q 190 00181 02 ...
Page 93: ...500 SERIES INSTALLATION MANUAL Page B 9 190 00181 02 Rev Q ...
Page 94: ...Page B 10 500 SERIES INSTALLATION MANUAL Rev Q 190 00181 02 ...