500 SERIES INSTALLATION MANUAL
Page 4-19
190-00181-02
Rev
Q
4.8
VOR/ILS INDICATOR (GNS 530 ONLY)
4.8.1 VOR/ILS Indicator Function
NOTE
Because the GNS 530 includes a “CDI” button that performs switching between GPS and
VOR/ILS on a remote indicator, it is seldom necessary to use these outputs to drive an
indicator. It is only necessary when it is desired for a separate indicator to display
VOR/ILS deviation full-time (regardless of the “CDI” button status).
The VOR/ILS indicator displays both lateral and vertical, To/From indications, lateral and vertical flags
and superflags. GNS 530 connector 5006 always outputs the VOR/Localizer/Glideslope navigation
information. The VOR/ILS pins on GNS 530 connector 5006 are used to drive an indicator that displays
VOR/ILS information at all times, regardless of the CDI selection on the GNS 530.
VOR/LOC COMPOSITE OUT is a standard VOR/Localizer Composite output signal which may be used
to drive the Left/Right, TO/FROM, and Flag indications of certain navigation indicators that contain an
internal converter.
The ILS ENERGIZE output goes low when the VLOC frequency is channeled to a localizer channel.
4.8.2 VOR/ILS Indicator Electrical Characteristics
4.8.2.1 Superflags
Pin Name
Connector
Pin
I/O
VOR/LOC SUPERFLAG
P5006
15
Out
GLIDESLOPE SUPERFLAG
P5006
38
Out
The Flag output supplies not less than 500 mA on a 28 volt system and 250 mA on a 14 volt system with
the output voltage not less than (AIRCRAFT POWER -3 Vdc) when the flag is to be OUT OF VIEW. The
output voltage with respect to ground is less than 3 Vdc when the flag is to be IN VIEW.
4.8.2.2 Deviation
Pin Name
Connector
Pin
I/O
VOR/LOC +LEFT
P5006
5
Out
VOR/LOC +RIGHT (VOR/LOC COMMON)
P5006
6
Out
GLIDUP
P5006
32
Out
GLIDDOWN/-FLAG (GLIDESLOPE
COMMON)
P5006 31
Out
The deviation outputs are each capable of driving up to three 1000
:
meter loads with
r
150 mVdc
r
10%
with respect to 2.5V Common for full-scale deflection. The drive circuit provides for more than full-scale
deflection with a maximum course deviation output voltage of ±300 mVdc
r
10%.
4.8.2.3 TO/FROM
Pin Name
Connector
Pin
I/O
VOR/LOC +TO
P5006
1
Out
VOR/LOC +FROM (VOR/LOC COMMON)
P5006
2
Out
The To/From outputs are capable of driving up to three 200
:
meter loads. When indicating TO, the output
is +225 ±75 mVdc
.
When indicating FROM, output is -225 ±75 mVdc
.
When invalid information is
present (Flag IN VIEW) the TO/FROM output is 0 ±10 mVdc
.
Summary of Contents for GNS 530
Page 84: ...Page A 4 500 SERIES INSTALLATION MANUAL Rev Q 190 00181 02 This page intentionally left blank ...
Page 86: ...Page B 2 500 SERIES INSTALLATION MANUAL Rev Q 190 00181 02 ...
Page 87: ...500 SERIES INSTALLATION MANUAL Page B 3 190 00181 02 Rev Q ...
Page 88: ...Page B 4 500 SERIES INSTALLATION MANUAL Rev Q 190 00181 02 ...
Page 89: ...500 SERIES INSTALLATION MANUAL Page B 5 190 00181 02 Rev Q ...
Page 90: ...Page B 6 500 SERIES INSTALLATION MANUAL Rev Q 190 00181 02 ...
Page 91: ...500 SERIES INSTALLATION MANUAL Page B 7 190 00181 02 Rev Q ...
Page 92: ...Page B 8 500 SERIES INSTALLATION MANUAL Rev Q 190 00181 02 ...
Page 93: ...500 SERIES INSTALLATION MANUAL Page B 9 190 00181 02 Rev Q ...
Page 94: ...Page B 10 500 SERIES INSTALLATION MANUAL Rev Q 190 00181 02 ...