Maintenance Manual
190-02472-02
G3X Touch EFIS Part 23 AML STC
Revision 2
Page 73
Reinstallation:
1. Place the GAD 29B in its mounting location and align its holes with the mounting holes.
2. Insert the four mounting screws and secure the GAD 29B in place.
3. Inspect the electrical connectors and pins for signs of damage. Repair any damage.
4. Connect the wiring harness to the GAD 29B.
5. Continue to section 7.7 for configuration and checkout procedures.
Figure 6-12 – GAD 29B
6.8
GDL 5XR Datalink
Removal:
1. Gain access to the GDL 5XR. Refer to the location information recorded in APPENDIX A of this
document and maintained with the aircraft records.
2. Disconnect the GDL 5XR electrical and coax cable connectors as applicable.
3. Remove the four screws that secure the GDL 5XR to the mounting location.
4. Lift the GDL 5XR off the mounting location.
Reinstallation:
1. Place the GDL 5XR in its mounting location and align its holes with the mounting holes.
2. Insert the four mounting screws and secure the GDL 5XR in place with washers and nuts (as
appropriate).
3. Inspect the electrical connector to ensure there are no bent or damaged pins. Repair any damage.
4. Connect the electrical and coax connectors as applicable to the GDL 5XR.
5. Continue to Section 7.8 for configuration and checkout procedures.