Maintenance Manual
190-02472-02
G3X Touch EFIS Part 23 AML STC
Revision 2
Page 43
Table 5-7 – Magnetometer Interference Test Sequence Example
Elapsed Time (From Start of Test)
(min:secs)
Action
0:00
Test Begins
0:10
Aileron Full Right
0:20
Aileron Full Left
0:30 Aileron
Level
0:40
Elevator Up
0:50 Elevator
Down
1:00
Elevator Level
1:20 Rudder
Left
1:40
Rudder Right
1:50 Rudder
Center
2:00
Flaps Down
2:10 Flaps
Up
2:20
Autopilot On
2:30 Autopilot
Off
2:40
Electric Trim (GFC 500)
2:50
Landing Gear Up
3:00
Landing Gear Down
3:10
Speed Brake Up
3:20
Speed Brake Down
3:30
Navigation Lights On
3:40
Navigation Lights Off
3:50
Landing Lights On
4:00
Landing Lights Off
4:10
Taxi Lights On
4:20
Taxi Lights Off
4:30
L Taxi Lights On
4:40
L Taxi Lights Off
4:50 Strobes
On
5:00
Strobes Off
5:10
Recognition Lights On
5:20
Recognition Lights Off
5:30
All Wing-Tip Lights On (simultaneous)
5:40
All Wing-Tip Lights Off (simultaneous)
5:50 Beacon
On
6:00
Beacon Off
6:10
Pitot Heat On
6:20
Pitot Heat Off
6:30 Test
Complete