background image

Pièce nº 1844063 (07/05)

Page 1

INSTRUCTIONS D’INST

ALLA

TION, 

D’UTILISATION ET D’ENTRETIEN 

DES FOURS À PIZZ

A GARLAND 

SÉRIE GPD À GAZ

POUR VO

TRE SÉCURITÉ

NE PAS ST

OCKER NI UTILISER D’ESSENCE OU 

D’AUTRES 

VA

PEURS OU LIQ

UIDES INFLAMMABLES 

À PRO

XIMITÉ DE CET APPAREIL OU DE 

TOUT 

AUTRE APP

AREIL. .

AVER

TISSEMENT :

UNE INSTALL

ATION, DES RÉGL

AGES, DES 

MODIFICATIONS, DES RÉP

ARATIONS OU UN 

ENTRETIEN MAL FAIT

S PEUVENT CA

USER 

DES DOMMAGES MA

TÉRIELS, DES BLESSURES 

OU LA

 MORT

. LIRE SOIGNEUSEMENT LES 

INSTRUCTIONS D’INST

ALLA

TION, D’UTILISATION 

ET D’ENTRETIEN AV

ANT D’INSTALLER OU DE 

RÉPARER L

’ÉQUIP

EMENT ..

LIRE T

OUTES LES SECTIONS DU PRÉSENT MANUEL ET LE CONSERVER POUR S’Y REPOR

TER UL TÉRIEUREMENT

.

CE PRODUIT A ÉTÉ HOMOL

OGUÉ EN T

ANT QU’ÉQ

UIPEMENT PR

OFESSIONNEL DE CUISSON ET DOIT ÊTRE 

INSTALLÉ P

AR DU PERSONNEL PR

OFESSIONNEL TEL Q

UE SPÉCIFIÉ. 

DANS L ’ÉT

AT

 DU MASSACHUSSET

S, L ’INST

ALLA

TION DE CE PRODUIT DOIT ÊTRE  RÉALISÉE P

AR UN PLOMBIER 

OU UN INSTALL

ATEUR A

GRÉÉ. NUMÉRO D’A

UTORISA

TION : G-1-07-05-28

Pour 

V otr

e Sécurité :

Placer dans un endr

oit bien en vue les instructions à suivr

e en cas d’odeur de gaz détectée par l

’utilisateur. Cette informatio

peut être obtenue aupr

ès du fournisseur de gaz local.

L ’at

tenti

on

 des u

til

isateu

rs e

st at

tiré

e sur l

e f

ait

 qu

e l’en

tre

tie

n et l

es répa

rat

ion

s doiv

ent ê

tre e

ff  ec

tu

és pa

r un

 agen

t d’en

tre

tie

auto

risé pa

r Garl

an

d uti

lis

an

t des p

ièc

es de re

ch

an

ge d’o

rig

in

e Garl

an

d. G

arl

an

d n’au

ra auc

un

e obl

iga

tio

n en c

e q

ui c

on

cer

ne 

n’im

port

e qu

el prod

uit m

al i

nst

all

é, ré

glé, u

til

isé o

u q

ui n

’au

rai

t pa

s été en

tre

tenu c

on

for

mém

en

t au

x co

des n

ati

on

aux e

t lo

cau

ou

 aux i

nst

ru

cti

on

s d

’in

stal

lat

ion

 fou

rn

ies

 ave

c le

 prod

uit o

u n

’im

port

e qu

el prod

uit d

on

t le

 nu

méro de sér

ie au

rai

t é

té m

uti

lé, 

oblit

éré

 ou s

uppr

im

é ou

 qui a

ura

it é

té mo

difi

 é o

u répa

ré avec

 des p

ièc

es n

on au

tor

isé

es o

u pa

r des a

gen

ts d

’en

tre

tie

n non 

auto

risé

s. Pou

r o

bten

ir l

a l

iste de

s agen

ts de ser

vic

e au

tori

sés, c

on

su

lter l

e si

te web de G

arl

an

d à : htt

p:/

/w

ww

.ga

rla

nd-

gro

up.

com. L

es ren

seign

em

en

ts c

on

tenu

s d

an

s le

 pré

sen

t doc

um

en

t (

y c

om

pri

s la c

on

cep

tio

n e

t le

s spéci

fi  ca

tio

ns de

s piè

ces

) peuven

être rem

pla

cés

 ou

 mod

ifi 

és s

ans

 préa

vis. 

L ’amélioration continuelle des pr

oduits est une politique Garland; par conséquent, la conception et les spécifi

 cations peuv

ent être modifi

 ées sans pr

éavis.

GARLAND COMMER

CIAL INDUSTRIES

185 East South S

treet

Freeland, P

ennsylvanie 18224

T éléphone : (570) 636-1000

T élécopieur : (570) 636-3903

GARLAND COMMER

CIAL RANGES, 

L TD.

1177 Kamato Road, M

ississauga, Ontario L4W 1X4

CANADA

T éléphone : 905-624-0260

T élécopieur : 905-624-5669

Enodis UK L

TD.

Swallo

wfi  eld 

Way

, H

ayes, M

iddlesex UB3 1DQ 

ANGLETERRE

T éléphone : 081-561-0433

T élécopieur : 081-848-0041

Pièce nº 1844063 (07/05)

© 2005 Garland Commer

cial Industries, I

nc.

Summary of Contents for GAS PIZZA OVENS

Page 1: ...performed by a Garland authorized service agent using genuine Garland replacement parts Garland will have no obligation with respect to any product that has been improperly installed adjusted operated...

Page 2: ...ld expose you to airborne particles of glass wool ceramic bers Inhalation of airborne particles of glass wool ceramic bers is known to the State of California to causes cancer Operation of this produc...

Page 3: ...Ventilation Canopy 7 Installing With Direct Ventilation 7 Assembly Instructions 7 Leg Installation 7 Hearth Installation 7 Double Deck Assembly 8 Gas Connection 8 Adjustments 9 Gas Pressure Adjustment...

Page 4: ...ar 10 WC 25mbar INPUT SPECIFICATIONS Natural Or Propane MODEL BTU HR KW GAS INLET GPD48 96 000 28 1 3 4 N P T GPD60 122 000 35 7 3 4 N P T GPD48 2 192 000 56 2 1 N P T GPD60 2 244 000 71 4 1 N P T Rat...

Page 5: ...plate a xed to the unit contains this information We suggest installation maintenance and repairs should be performed by your local authorized service agency listed in your information manual pamphle...

Page 6: ...nd clear from combustibles 5 These units must be installed under an adequate ventilation system Refer to sections titled Ventilation and Air Supply for further instructions Ventilation This appliance...

Page 7: ...ed in the ue line as close to the oven connection as possible An adequately sized prefabricated metal vent should rise at least feet m above the roof of the building in which it is installed or feet m...

Page 8: ...cure legs to lower section 2 Remove stainless steel top trim strip from lower unit if not already removed 3 Tip upper unit backward Remove vent patch at lower rear if not if not already removed 4 Plac...

Page 9: ...the unit and it is installed on the manifold downstream of the main valve The gas pressure must be checked when the unit is installed to ensure that the unit gas pressure is the same as speci ed on t...

Page 10: ...may indicate that not enough air is mixing with the gas If this case back o the air adjustment disk until the proper ame and color is set By Pass Flame Adjustment The by pass in the thermostat is a sm...

Page 11: ...CONTROL IS OUT MORE THAN DEGREES FAHRENHEIT FROM THE DIAL SETTING THE CONTROL WILL BE REPLACED UNDER WARRANTY WITHIN THE WARRANTY PERIOD Flame Diverters Flame diverters distribute the heat evenly bel...

Page 12: ...t lighting procedure unless the pilot is extinguished by any cause 8 To shut down unit turn gas cock on combination control to the OFF position Oven Exterior Painted Surfaces should be cleaned when co...

Page 13: ...pass ame high Reduce by pass ame Thermostat Check actual temperature call for service Color overall light Short bake time Bake longer Lower temperature Increase temperature Dough Check dough for fresh...

Page 14: ...Part 1844063 08 06 Page 14 NOTES...

Page 15: ...de d rivation Thermostat V ri er la temp rature r elle appelerun technicien d entretien Couleur trop claire Temps de cuisson trop court Prolonger la cuisson Temp rature basse Augmenter la temp rature...

Page 16: ...e en position OFF Ext rieur Du Four Les surfaces peintes doivent tre nettoy es froid en utilisant une solution de savon doux et d eau ti de sur un chi on propre ou une ponge Rincer et bien ass cher a...

Page 17: ...tionner 2 De nombreuses pi ces du four sont couverte d huile de protection Cette huile doit tre br l e avant d utiliser le four pour la pr paration de denr es alimentaires Il est normal que l appareil...

Page 18: ...voquer des fuites de gaz autour de la vis de r glage talonnage 1 L talonnage sur place est rarement n cessaire et avant de le faire il convient de s assurer que les r sultats de cuisson prouvent que l...

Page 19: ...sque de r glage et en l loignant de la gorge de m lange d air on augmente la quantit d air dans le m lange jusqu ce que le jaune disparaisse et qu on obtienne une amme bleu vif 4 Lorsque la amme devie...

Page 20: ...l un se trouve sur le cot droit et l autre dans le coin arri re droit 5 Le branchement de cot droit est quip d un bouchon carr creux de 3 4 po Si ce branchement est utilis il faut boucher la connexio...

Page 21: ...le GPD 48 est quip de deux 2 plaques de sole Le mod le GPD 60 est quip de trois 3 plaques de sole 5 Instruction d installation pour la sole a Placer un tournevis ou un autre dispositif de levier simi...

Page 22: ...tionnant sous une hotte de ventilation doivent tre quip s d un ensemble de d ecteur de conduit de fum e de hotte fourni pour compenser un tirade trop fort Installation Avec Une Ventilation Directe Cha...

Page 23: ...bles C t s de po mm et arri re de po mm Convient pour installation sur sols combustibles Les pieds doivent tre install s Pr paration 1 Retirer soigneusement l appareil de son emballage Enlever les ls...

Page 24: ...it de l appareil Pour correspondre avec l usine ou le centre de service agr local concernant des probl mes de service ou des pi ces de rechange bien faire r f rence l appareil avec le num ro de mod le...

Page 25: ...IFICATIONS D ENTR E Gaz Naturel Ou Propane MOD LE BTU HR KW Entr e Gaz GPD48 96 000 28 1 3 4 Po N P T GPD60 122 000 35 7 3 4 Po N P T GPD48 2 192 000 56 2 1Po N P T GPD60 2 244 000 71 4 1Po N P T Les...

Page 26: ...Installation Avec Une Ventilation Directe 7 Instructions D assemblage 8 Installation Des Pieds 8 Installation De La Sole 8 Assemblage Du Four Deux Sections 8 Branchement De Gaz 9 R glages 10 R glages...

Page 27: ...es c ramiques en suspension dans l air L inhalation des particules de laine de verre bre c ramique en suspension dans l air est connue dans l tat de Californie comme pouvant causer le cancer L utilisa...

Page 28: ...n et les r parations doivent tre e ectu s par un agent d entretien autoris par Garland utilisant des pi ces de rechange d origine Garland Garland n aura aucune obligation en ce qui concerne n importe...

Reviews: