UP FOLDING WALL MOUNT
9
Install the outer pipe weldments to the hinge points on the lower two wood pads. Install the bushings
(Item 6) into both sides of the pipe before installing the pipe into the hinge bracket.
Once the pipe has been installed into the hinge bracket and the ½” x 3 1/2” bolt is installed, add the
½” nylon lock nut and tighten until the nut just engages the hinge bracket.
Do not overtighten the nut as this will cause binding and excessive wear on the bushings and the
outer tube.
The attachment is the same for all four pipes.
Slide the inner extension pipes into
the outer extension pipes. Install a
flange bushing (Item 6) on each
side of the inner extension tubes.
Install the hinge brackets onto each
inner pipe and
Install the ½” x 3 1/2” bolt and add
the ½” nylon lock nut and tighten
until the nut just engages the hinge
bracket.
Do not overtighten the nut as this
will cause binding and excessive
wear on the bushings and the inner
tube.
Slide the extension tube until the
distance from the wall to the face of the hinge bracket is equal to the FOB – 2.5” or FOB – 11.5”
when a height adjuster is to be used.
Install the set screw (Item 28) into the outer extension tube and lightly tighten the set screw.