63
ITEM
COMMAND
USAGE
DESCRIPTION
PROG 7982 BAKUP:
0
PROG 7982 BAKUP:
1
Back-up
Method
BAKUP
PROG 7982 BAKUP:
2
To set back up method (for both Areas):
0
Æ
Back up None
1
Æ
Back up 1
2
Æ
Back up 2
PROG 7982 ASSIG:
0
Retry Method
ASSIG
PROG 7982 ASSIG:
1
To set retry method (for both Areas):
0
Æ
One by one
1
Æ
Alternative
PROG 7982 WARNB:
10
To set
warning beep volume:
(only Area1)
10
Æ
1 (Area 1) 0 (function disable)
PROG 7982 WARNB:
11
11
Æ
1 (Area 1) 1 (low volume)
PROG 7982 WARNB:
12
12
Æ
1 (Area 1) 2 (high volume)
Warring-Beep WARNB
PROG 7982 TCODE:2
12340
PROG 7982 EXARM:
100
A Exit Time
EXARM
PROG 7982 EXARM:
270
To set away exit time; (00 for 0 sec, 10 for 10 sec, …, 70 for 70 sec)
100
Æ
1 (area 1) 00 (for 0 sec)
270
Æ
2 (area 2) 70 (for 70 secs)
PROG 7982 ENARM:
100
A Entry Time
ENARM
PROG 7982 ENARM:
240
To set away entry time: (00 for 0 sec, 10 for 10 sec, …, 70 for 70 sec)
100
Æ
1 (area 1) 00 (for 0 sec)
240
Æ
2 (area 2) 40 (for 40 secs)
PROG 7982 EXHOM:
100
H Exit Time
EXHOM
PROG 7982 EXHOM:
270
To set home exit time: (00 for 0 sec, 10 for 10 sec, …, 70 for 70 sec)
100
Æ
1 (area 1) 00 (for 0 sec)
270
Æ
2 (area 2) 70 (for 70 secs)
PROG 7982 ENHOM:
100
H Entry Time
ENHOM
PROG 7982 ENHOM:
240
To set home exit time: (00 for 0 sec, 10 for 10 sec, …, 70 for 70 sec)
100
Æ
1 (area 1) 00 (for 0 sec)
240
Æ
2 (area 2) 40 (for 40 secs)
PROG 7982 MCODE:
12222
Master Code
MCODE
PROG 7982 MCODE:
22222
To change master code:
12222
Æ
1 (Area 1) 2222 (new master code)
22222
Æ
2 (Area 2) 2222 (new master code)
PROG 7982 DCODE:
13333
Duress Code
(see Note 3)
DCODE
PROG 7982 DCODE:
23333
To change duress code:
12222
Æ
1 (Area 1) 3333 (new duress code)
22222
Æ
2 (Area 2) 3333 (new duress code)
PROG 7982 MOBIL:
10/20
1
Æ
1 (Area 1) 0 (Disable) 2
Æ
2 (Area 2) 0 (Disable)
PROG 7982 MOBIL:
11/21
1
Æ
1 (Area 1) 1 (4Hours) 2
Æ
2 (Area 2) 1 (4Hours)
PROG 7982 MOBIL:
12/22
1
Æ
1 (Area 1) 2 (8Hours) 2
Æ
2 (Area 2) 2 (8Hours)
Mobility
MOBIL
PROG 7982 MOBIL:
13/23
1
Æ
1 (Area 1) 3 (12Hours) 2
Æ
2 (Area 2) 3 (12Hours)
PROG 7982 ACRPT:
0
AC Failure
Report
ACRPT
PROG 7982 ACRPT:
1
To set
AC failure report function:
0
Æ
function disable
1
Æ
function enable
PROG 7982 ALENG:
102
102
Æ
1(Area 1) 02 (Alarm length
is 2 min),
Alarm Length
ALENG
PROG 7982 ALENG:
215
215
Æ
2(Area 2) 15 (Alarm length
is 15 min)
Alarm length can be Disable
to 15 mins (00 for Disable…
02 for 2 Min, …, 10 for 10
mins,…, and 15 for 15 mins).
PROG 7982 LSIRN:
10/20
To set local siren function:
10
Æ
1 (Area 1) 0 (function disable)
20
Æ
2 (Area 2) 0 (function disable)
Local Siren
LSIRN
PROG 7982 LSIRN:
11/21
11
Æ
1 (Area 1) 1 (function enable)
21
Æ
2 (Area 2) 1 (function enable)
PROG 7982 TAMPE:
0
Tamper TAMPE
PROG 7982 TAMPE:
1
0
Æ
Normal
1
Æ
Away Only